12. SPEAKER

 Terminals.  These plug-in 4-terminal screw type connectors permit speaker wire sizes up

to 12 gauge. When making connections for the STEREO mode, be sure to observe the "

+

"  and "

"

polarity markings, just under the LEFT & RIGHT markings, for each wire pair going to the speakers.

CAUTION:

  When making connections for the BRIDGED mode, remember, only one speaker is being

attached per amplifier pair.   Be sure to observe the outer "

+

"  and "

" polarity markings on each side

of the word "BRIDGED" on the panel above the 4-terminal connector when connecting the 2-conductor
wire to the speaker.

13. REMOTE MASTER ON/OFF CONTROL

. This 2-terminal connector allows the entire PA1235 to be

powered ON and OFF by a control voltage ranging between 5 and 30 Volts DC (16mA @ 12 V).  Be
sure to observe the marked polarity.  For instance, the 12 volt common CO (Control Output) of the
Xantech ZPR68 preamp will power the PA1235 ON and OFF automatically with the first zone ON and
last zone OFF commands.

The DC Voltage must be applied continuously to retain the ON condition and drop to less than 0.5 Volt
to switch to the OFF condition.

NOTE:

 

The front panel POWER switch (item #3) must be left in the Manual OFF (Out) position

and the Master AC Line Switch (item #17) set to ON (I) to permit the REMOTE MASTER ON/OFF
CONTROL to operate.

See also CAUTION notes, Fig. 9.

14. Rear Panel ON/OFF LED

.  This LED indicates the power ON/OFF condition of the entire PA1235,

whether activated by a REMOTE MASTER ON/OFF CONTROL voltage (item #13) or from the front
panel POWER switch (item # 3).

15.

Common 

IR IN

 and 

STATUS

 Connector. This 4-terminal connector provides the same type of IR

control functions as that of the individual amplifier pairs (item #11) except they apply to all amplifier
pairs in common.  That is, IR commands for Volume, Mute, etc., control all amplifier pairs together.

NOTE:

  Individual control of amplifier pairs is possible, however, through the Common IR IN, provided

the IR Code Group is changed on amplifier pairs you wish to control separately.

The STATUS output goes high and low with the AC Power ON/OFF state of the entire PA1235.  It does
not respond to a Common IR OFF/ON (Standby) condition.

16. Grounding Screw

.  Provides a means for chassis connection to earth ground or to other A/V products

to aid in the reduction of system noise, etc., where needed.

17.

Master 

AC LINE ON/OFF

 Switch.  Turns power OFF to the entire PA1235, regardless of IR, Control

IN, or front panel POWER switch conditions.  Must be placed in the ON (

I

) position for the other power

switching functions to work.

18. 3-Conductor AC Line Cord Receptacle

.  Standard IEC male receptacle for plug-in of a 3-conductor

power line cord.  Depending on the application, plug the line cord into a switched or un-switched 120V
60 Hz AC outlet (or 240 VAC 50 Hz on the 240 V version).

RC68+ (or RC68) PROGRAMMER / REMOTE CONTROL

The RC68+ Programmer (available separately) contains all the commands necessary to operate the IR
control functions of the PA1235.

• You will need it to program universal learning devices such as the Xantech URC-2 learning remote, the

Xantech Smart Pads, the 590 Programmable Controller, the 710 Fone Link, etc., with commands that
operate the PA1235.

NOTE:

 The RC68+ codes operate many other Xantech models as well, such as the RGC11, CC12,

ZPR68, etc.  Therefore, 

only the button descriptions that apply to the operation of the PA1235 are

listed below

.  All others should be ignored.

CAUTION:

  While the RC68+ can be used as a handheld remote control, it is highly recommended it

not be given to the final user for the following reasons:

PA1235

Summary of Contents for PA1235

Page 1: ...arge single multiple filtered power supply delivers high quality at a reasonable price IR Controlled Volume Level Volume can be ramped from zero output to maximum for individual channel pairs or as gr...

Page 2: ...12 Volt common CO Control Output on the Xantech ZPR68 to power one or more PA1235 s ON and OFF automatically with first zone ON and last zone OFF commands Default settings As received from the factor...

Page 3: ...range within 5 dB of MAX V the LED color changes from Green to Red NOTE Red indicates that volume is approaching maximum not an indication of power output level 5 Line Inputs These RCA type jacks are...

Page 4: ...VDC output 9V 70 mA with ON condition 0 Volts output OFF Standby GROUND Ground for IR IN STATUS out CI in CI Control Input Use for control of Standby ON OFF of amplifier pairs if desired instead of b...

Page 5: ...l amplifier pairs item 11 except they apply to all amplifier pairs in common That is IR commands for Volume Mute etc control all amplifier pairs together NOTE Individual control of amplifier pairs is...

Page 6: ...en the CI terminal is driven high with an external control voltage Refer also to items 9 and 11 Fig 3 4 C BAL Command Instantly returns the balance to the Center position equal volume in each channel...

Page 7: ...s in the PA1235 are set to code group number A0 Be sure to set the RC68 to the same number It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to address each...

Page 8: ...nd screws supplied NOTE You should consider some sort of rear support for rack mounted units when used in mobile applications or when located in seismically active areas CONNECTING THE PA1235 When mak...

Page 9: ...For such applications use the STEREO mode Use the BRIDGED mode for single speaker higher power applications such as in surround sound systems Use speakers with an impedance rating of 8 Ohms minimum T...

Page 10: ...control to the RS41AV and the Source Components and to power the keypads and IR receivers three leads are connected between the CB18 and a 789 44 Connecting Block 6 Since a common IR bus is used to k...

Page 11: ...R CA AC 120V 60 HZ 4 AMP LEVEL RESET RIGHT 0 9 8 6 7 4 5 2 3 1 GND 12V CB18 Parallel Connecting Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWE...

Page 12: ...ion in each room It also carries a COMMON IR signal to a 789 44 Connecting Block for control of the RS41AV Remote Switcher and the Source Components 2 Note that the ZONE numbers on the 796 20 do not a...

Page 13: ...EKEEP IR The PA1235 has been designed specifically to work well with both Zone and All Zone ON OFF management as rendered by the ZPR68 10 In this example the STATUS GND output 0 to 12 VDC of each zone...

Page 14: ...IN G 12 IN G 12 IN G ZONE 6 ZONE 5 ZONE 4 ZONE IR INPUTS 12 IN G 12 IN G 12 IN G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTI...

Page 15: ...does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position 5 PA1235 becomes very warm shuts OFF but does not come bac...

Page 16: ...z to 55 kHz Input Sensitivity Rated Power stereo mode Input Gain IR Controlled Setting Max 0 5 V Default 1 0 V Min Off Input Impedance LOCAL Inputs 22 kOhms COMMON AUDIO BUS Inputs 70 kOhms Power Sour...

Reviews: