8.

To keep the system cost low, no AC power management is included.  The user would need to operate
the power switching for each component individually, using front panel power switches, or IR, as
appropriate.

Individual room Standby ON/OFF is provided, however. The STATUS of Standby ON/OFF is indicated
at the IR receivers and keypads via the STATUS line connection to each room, as shown.

9.

This system is primarily set up to distribute music to each room.  A video feed to a single room could
also be done at low cost.  However, video distribution to all rooms would add additional layers of
complexity and cost that would best be handled by a ZPR68-10 in a system similar to that shown in

Fig. 11

.

10.

When connecting speakers for each room, be sure to observe correct polarities as shown in 

Fig. 6

.

A Basic Dedicated IR System - Non Dedicated Keypads and Remotes.

A typical system of this type is shown in 

Fig. 10

, where each remote room has a Dedicated IR path going

to the PA1235 amplifier pair that controls it.  The IR bus is not connected in common as it is in 

Fig. 8

. It

eliminates the need for dedicated remotes, 

allowing you to carry the same remote(s) from room-to-

room 

- that is, remote commands for Volume, Mute, etc., will work in any room from the same remote.

This system is similar in many respects to the previous system (Fig. 8), but differs as follows:

1.

A 796-20 Six Zone Connecting Block is used to "zone" individual IR control signals to each amplifier
pair of the PA1235 for Volume, Mute, Balance and Standby ON/OFF action in each room.  It also
carries a "COMMON" IR signal to a 789-44 Connecting Block for control of the RS41AV Remote
Switcher and the Source Components.

2.

Note that the ZONE numbers on the 796-20 do not agree with the room or amplifier pair numbers.  This
is of no consequence; it is only necessary that each room's keypad or IR receiver connects to a different
ZONE IR INPUT on the 796-20.

3.

Since the 796-20 channels the IR from each room to it's specific PA1235 amplifier pair, each amplifier
pair can use the same IR Code Group (the factory default 

A0

).

4. While use of the 796-20 entails some added expense, it reduces programming time for both the hand-

held remotes and the keypads, in addition to providing additional convenience to the user.

5.

The desired volume and other commands from the RC68+ Programmer (see 

Fig. 4

) need to be

"taught" into learning remote controls (such as the Xantech URC types) and Smart Pads used in the
system, either directly or by using Dragon Drop IR™.

Connecting the REMOTE MASTER ON/OFF CONTROL Terminals

As mentioned under "PA1235 PANEL AND FEATURE DESCRIPTIONS", the REMOTE MASTER ON/OFF
CONTROL terminals allow the power to the entire PA1235 to be turned ON and OFF by a remotely applied
DC Voltage.  

Figs. 9

 and 

11

 are typical applications using this feature.

Using a DC Power Adapter as a Control Voltage

Fig. 10

 illustrates how a PA1235 can be switched ON and OFF via the switched AC outlet on the rear of

a preamplifier or other control center.

• When the preamplifier Power Switch is switched ON, power is applied to the DC adapter which in turn

applies 5 V to 30 VDC to the PA1235, switching it ON.

• Similarly, when the preamplifier is switched OFF, the DC voltage to the PA1235 is removed, turning it

OFF.

PA1235

Summary of Contents for PA1235

Page 1: ...arge single multiple filtered power supply delivers high quality at a reasonable price IR Controlled Volume Level Volume can be ramped from zero output to maximum for individual channel pairs or as gr...

Page 2: ...12 Volt common CO Control Output on the Xantech ZPR68 to power one or more PA1235 s ON and OFF automatically with first zone ON and last zone OFF commands Default settings As received from the factor...

Page 3: ...range within 5 dB of MAX V the LED color changes from Green to Red NOTE Red indicates that volume is approaching maximum not an indication of power output level 5 Line Inputs These RCA type jacks are...

Page 4: ...VDC output 9V 70 mA with ON condition 0 Volts output OFF Standby GROUND Ground for IR IN STATUS out CI in CI Control Input Use for control of Standby ON OFF of amplifier pairs if desired instead of b...

Page 5: ...l amplifier pairs item 11 except they apply to all amplifier pairs in common That is IR commands for Volume Mute etc control all amplifier pairs together NOTE Individual control of amplifier pairs is...

Page 6: ...en the CI terminal is driven high with an external control voltage Refer also to items 9 and 11 Fig 3 4 C BAL Command Instantly returns the balance to the Center position equal volume in each channel...

Page 7: ...s in the PA1235 are set to code group number A0 Be sure to set the RC68 to the same number It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to address each...

Page 8: ...nd screws supplied NOTE You should consider some sort of rear support for rack mounted units when used in mobile applications or when located in seismically active areas CONNECTING THE PA1235 When mak...

Page 9: ...For such applications use the STEREO mode Use the BRIDGED mode for single speaker higher power applications such as in surround sound systems Use speakers with an impedance rating of 8 Ohms minimum T...

Page 10: ...control to the RS41AV and the Source Components and to power the keypads and IR receivers three leads are connected between the CB18 and a 789 44 Connecting Block 6 Since a common IR bus is used to k...

Page 11: ...R CA AC 120V 60 HZ 4 AMP LEVEL RESET RIGHT 0 9 8 6 7 4 5 2 3 1 GND 12V CB18 Parallel Connecting Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWE...

Page 12: ...ion in each room It also carries a COMMON IR signal to a 789 44 Connecting Block for control of the RS41AV Remote Switcher and the Source Components 2 Note that the ZONE numbers on the 796 20 do not a...

Page 13: ...EKEEP IR The PA1235 has been designed specifically to work well with both Zone and All Zone ON OFF management as rendered by the ZPR68 10 In this example the STATUS GND output 0 to 12 VDC of each zone...

Page 14: ...IN G 12 IN G 12 IN G ZONE 6 ZONE 5 ZONE 4 ZONE IR INPUTS 12 IN G 12 IN G 12 IN G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTI...

Page 15: ...does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position 5 PA1235 becomes very warm shuts OFF but does not come bac...

Page 16: ...z to 55 kHz Input Sensitivity Rated Power stereo mode Input Gain IR Controlled Setting Max 0 5 V Default 1 0 V Min Off Input Impedance LOCAL Inputs 22 kOhms COMMON AUDIO BUS Inputs 70 kOhms Power Sour...

Reviews: