7. MUTE ON

/

OFF

.  Separate ON / OFF Mute commands give positive mute action without knowing the

actual mute status.  This is very helpful in a remote room where commands are sent “blind” without
any visual aids for status.

NOTE

:  In addition to MUTE OFF, the muted condition can be released with VOLume (item #8), Preset

Level (item #2) and Balance (items #4 & 5) commands.

8. VOLume 

Up/Down Commands.  When pressed in individual steps, volume increase and decrease is

2 dB per step over a range of 0 dB (Max.) to -60 dB.  The next step below -60 dB is OFF (> -90 dB).
When pressed continuously, volume level will change (ramp) continuously in 1 dB steps.  See also
MAX-V settings (item 6).

NOTE:

  Volume action of the PA1235 has been designed specifically to ramp more quickly in the

DOWN direction and more slowly in the UP direction.

9. Code Group Numbers. 

The PA1235 is capable of being set to 55 different code groups, both

individually as amplifier pairs and collectively as a group.

NOTE:   

As shipped from the factory, all amplifier pairs in the PA1235 are set to code group number

A0.

Be sure to set the RC68+ to the same number!

It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to
address each pair individually from the COMMON IR BUS (item #15, 

Fig. 3

) or an external common

IR bus network when using other Xantech PA1235's in large systems, to avoid mutual interaction.

Refer to the RC68+ instructions for code group setting procedures

.

10. ADJ-OFF

 Command.   This command unlocks a previous MAX-V setting.  See also item #6.

INSTALLATION

PHYSICAL LOCATION AND MOUNTING

When you mount the PA1235, you should plan its location carefully.  Pay close attention to each of the
following factors:

1.

The amplifier is convection cooled.  That is, it depends on the natural free flow of air up through the
slot perforations in the bottom plate, over the internal heat dissipating fins, then out the top cover, for
adequate cooling.

Upper shelf, component, wall, etc.

2-inch spacing
(minimum)

PA1235

To maximize air flow, route
single large opening in lower shelf.

Keep perforations on top cover free of
obstructions for max. cooling effect.

Keep perforations on bottom
plate free of obstructions.

Convection

Airflow

Fig. 5   

Horizontal Mounting

PA1235

Summary of Contents for PA1235

Page 1: ...arge single multiple filtered power supply delivers high quality at a reasonable price IR Controlled Volume Level Volume can be ramped from zero output to maximum for individual channel pairs or as gr...

Page 2: ...12 Volt common CO Control Output on the Xantech ZPR68 to power one or more PA1235 s ON and OFF automatically with first zone ON and last zone OFF commands Default settings As received from the factor...

Page 3: ...range within 5 dB of MAX V the LED color changes from Green to Red NOTE Red indicates that volume is approaching maximum not an indication of power output level 5 Line Inputs These RCA type jacks are...

Page 4: ...VDC output 9V 70 mA with ON condition 0 Volts output OFF Standby GROUND Ground for IR IN STATUS out CI in CI Control Input Use for control of Standby ON OFF of amplifier pairs if desired instead of b...

Page 5: ...l amplifier pairs item 11 except they apply to all amplifier pairs in common That is IR commands for Volume Mute etc control all amplifier pairs together NOTE Individual control of amplifier pairs is...

Page 6: ...en the CI terminal is driven high with an external control voltage Refer also to items 9 and 11 Fig 3 4 C BAL Command Instantly returns the balance to the Center position equal volume in each channel...

Page 7: ...s in the PA1235 are set to code group number A0 Be sure to set the RC68 to the same number It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to address each...

Page 8: ...nd screws supplied NOTE You should consider some sort of rear support for rack mounted units when used in mobile applications or when located in seismically active areas CONNECTING THE PA1235 When mak...

Page 9: ...For such applications use the STEREO mode Use the BRIDGED mode for single speaker higher power applications such as in surround sound systems Use speakers with an impedance rating of 8 Ohms minimum T...

Page 10: ...control to the RS41AV and the Source Components and to power the keypads and IR receivers three leads are connected between the CB18 and a 789 44 Connecting Block 6 Since a common IR bus is used to k...

Page 11: ...R CA AC 120V 60 HZ 4 AMP LEVEL RESET RIGHT 0 9 8 6 7 4 5 2 3 1 GND 12V CB18 Parallel Connecting Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWE...

Page 12: ...ion in each room It also carries a COMMON IR signal to a 789 44 Connecting Block for control of the RS41AV Remote Switcher and the Source Components 2 Note that the ZONE numbers on the 796 20 do not a...

Page 13: ...EKEEP IR The PA1235 has been designed specifically to work well with both Zone and All Zone ON OFF management as rendered by the ZPR68 10 In this example the STATUS GND output 0 to 12 VDC of each zone...

Page 14: ...IN G 12 IN G 12 IN G ZONE 6 ZONE 5 ZONE 4 ZONE IR INPUTS 12 IN G 12 IN G 12 IN G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTI...

Page 15: ...does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position 5 PA1235 becomes very warm shuts OFF but does not come bac...

Page 16: ...z to 55 kHz Input Sensitivity Rated Power stereo mode Input Gain IR Controlled Setting Max 0 5 V Default 1 0 V Min Off Input Impedance LOCAL Inputs 22 kOhms COMMON AUDIO BUS Inputs 70 kOhms Power Sour...

Reviews: