REMOTE MASTER

ON/OFF CONTROL

5-30 VOLTS DC

+

--

COMMON BUS

LOCAL

LEFT

RIGHT

STEREO

MONO

BRIDGED

CI

GROUND

ST

A

TUS

IR IN

LEFT

RIGHT

SPEAKER

+

-- --

+

 

+

  

BRIDGED  

--

2

COMMON BUS

LOCAL

LEFT

RIGHT

STEREO

MONO

BRIDGED

CI

GROUND

ST

A

T

AUS

IR IN

LEFT

RIGHT

SPEAKER

+

-- --

+

 

+

  

BRIDGED  

--

3

CAUTION

RISK OF ELECTRIC

SHOCK. DO NOT OPEN

MODE

MODE

5V to 12 VDC Adapter,

such as a Xantech 781RG,

plugged into a Switched

AC Outlet on Preamplifier

Preamplifier, Control Center, etc.

This 

must 

 be the positive

 (+)

lead (

white striped

 lead on

Xantech Power Supply Adapters).

PA1235

(portion of rear panel)

(+)

CAUTION:

You 

must

 use the included

220 

 resistor. See

CAUTION note above.

Fig. 9

Using the REMOTE MASTER ON/OFF
CONTROL Terminals

CAUTION: 

 The output voltage of some adapters, such as the 781RG, drops off too slowly to provide

a quick turnoff for the PA1235.  Therefore, when using 

any

 adapter (12 VDC max), 

always

 connect the

included 220 Ohm 1 Watt resistor in shunt with the REMOTE MASTER ON /OFF CONTROL terminals
as shown in 

Fig.9

.  Failure to do so may result in blowing of the power line fuse (item #10, 

Fig.3

)

NOTE:

   Do not use the 220 Ohm resistor when connecting to the CO terminals of a ZPR68!

A Multi-Zone Power Managed System, using a  ZPR68, a GATEKEEP-IR

 and a PA1235

Fig. 11

 shows a PA1235 in a typical multi-room system with a Xantech ZPR68-10 six-zone preamp and a

GATEKEEP-IR.  The PA1235 has been designed specifically to work well with both Zone and All-Zone ON/
OFF management as rendered by the ZPR68-10.

In this example, the 

STATUS

 & 

GND

 output (0 to +12 VDC) of each zone of the ZPR68-10 is connected,

via a 2-conductor lead, to the 

CI

 & 

GROUND

 of each amplifier pair on the PA1235.

• This causes the ON/OFF condition of any given ZPR68-10 Zone to turn it's corresponding amplifier pair

ON/OFF (Standby ON/OFF).

Also, the common 

CO

 (control output, 0 to +12 VDC ) from the ZPR68-10 is used to drive the 

REMOTE

MASTER ON/OFF CONTROL

 terminals of the PA1235.

CAUTION:

  When making this connection, 

do not

  use the included 220 Ohm resistor! Refer also to

CAUTION notes, 

Fig. 9

.

• When any one of the zones is turned ON, the common CO goes high (+12V), turning on power to the

entire PA1235.

• Similarly, when the last zone is turned OFF, the CO drops to 0 V, turning the PA1235 totally OFF.

NOTE:

  No IR control of the PA1235 is used in the system shown in 

Fig. 11

.  All volume, mute, etc. functions

are handled by IR control of the ZPR68-10.  The PA1235 amplifier pairs are all set to the default volume
level setting by pressing the LEVEL (System) RESET button (refer to item #9, 

Fig. 3

).

AC Power Management of the entire system as shown in 

Fig. 11

 is accomplished, therefore, as follows:

a) The PA1235 is controlled via the STATUS and CO functions as noted above.

b) The Source Components are controlled via the GATEKEEP-IR

 sensor system and the IR macros in

the Smart Pads and, where used, IR macros in Learning Remotes (such as the Xantech URC types).

PA1235

Summary of Contents for PA1235

Page 1: ...arge single multiple filtered power supply delivers high quality at a reasonable price IR Controlled Volume Level Volume can be ramped from zero output to maximum for individual channel pairs or as gr...

Page 2: ...12 Volt common CO Control Output on the Xantech ZPR68 to power one or more PA1235 s ON and OFF automatically with first zone ON and last zone OFF commands Default settings As received from the factor...

Page 3: ...range within 5 dB of MAX V the LED color changes from Green to Red NOTE Red indicates that volume is approaching maximum not an indication of power output level 5 Line Inputs These RCA type jacks are...

Page 4: ...VDC output 9V 70 mA with ON condition 0 Volts output OFF Standby GROUND Ground for IR IN STATUS out CI in CI Control Input Use for control of Standby ON OFF of amplifier pairs if desired instead of b...

Page 5: ...l amplifier pairs item 11 except they apply to all amplifier pairs in common That is IR commands for Volume Mute etc control all amplifier pairs together NOTE Individual control of amplifier pairs is...

Page 6: ...en the CI terminal is driven high with an external control voltage Refer also to items 9 and 11 Fig 3 4 C BAL Command Instantly returns the balance to the Center position equal volume in each channel...

Page 7: ...s in the PA1235 are set to code group number A0 Be sure to set the RC68 to the same number It may be necessary to change the PA1235 amplifier pairs to different code groups if you wish to address each...

Page 8: ...nd screws supplied NOTE You should consider some sort of rear support for rack mounted units when used in mobile applications or when located in seismically active areas CONNECTING THE PA1235 When mak...

Page 9: ...For such applications use the STEREO mode Use the BRIDGED mode for single speaker higher power applications such as in surround sound systems Use speakers with an impedance rating of 8 Ohms minimum T...

Page 10: ...control to the RS41AV and the Source Components and to power the keypads and IR receivers three leads are connected between the CB18 and a 789 44 Connecting Block 6 Since a common IR bus is used to k...

Page 11: ...R CA AC 120V 60 HZ 4 AMP LEVEL RESET RIGHT 0 9 8 6 7 4 5 2 3 1 GND 12V CB18 Parallel Connecting Block 780 80 J Box IR Receiver ROOM 2 R L ST G V IR ROOM 1 R L Smart Pad 3 ST G V IR IR CONFIRM V V POWE...

Page 12: ...ion in each room It also carries a COMMON IR signal to a 789 44 Connecting Block for control of the RS41AV Remote Switcher and the Source Components 2 Note that the ZONE numbers on the 796 20 do not a...

Page 13: ...EKEEP IR The PA1235 has been designed specifically to work well with both Zone and All Zone ON OFF management as rendered by the ZPR68 10 In this example the STATUS GND output 0 to 12 VDC of each zone...

Page 14: ...IN G 12 IN G 12 IN G ZONE 6 ZONE 5 ZONE 4 ZONE IR INPUTS 12 IN G 12 IN G 12 IN G A B A B A B ZONE 4 ZONE 5 ZONE 6 12 OUT G SYLMAR CA MADE IN U S A ZONE EMITTERS ZONE EMITTERS 796 20 SIX ZONE CONNECTI...

Page 15: ...does not turn OFF when REMOTE input voltage goes to 0 Volts Be sure that the POWER switch item 3 Fig 2 is set to the MANUAL OFF Out position 5 PA1235 becomes very warm shuts OFF but does not come bac...

Page 16: ...z to 55 kHz Input Sensitivity Rated Power stereo mode Input Gain IR Controlled Setting Max 0 5 V Default 1 0 V Min Off Input Impedance LOCAL Inputs 22 kOhms COMMON AUDIO BUS Inputs 70 kOhms Power Sour...

Reviews: