M99 minifant operating instructions
Version M99E 20.02.2014
Page 22 of 35
5.4 Frequency converter-parameter set for DS and DS-pro models
The parameters which are not listed are in the manufacturer's factory settings.
Parameter set ATV12 (M99-DS)
V1.0.2
Code
Description
750 W 4 pol.
Factory setting
ACC Run-up
time
2.0 s
3.0 s
dEC Starting
time
1.0 s
3.0 s
LSP Low
frequency
30.0 Hz
0 Hz
tFr
Maximum Output frequency
70.0 Hz
60.0 Hz
HSP High
frequency
70.0 Hz
50.0 oder 60.0 Hz
nPr
Motor power rating
0.75 kW
0.75 kW
TCT
Model 2- wire-control
LEL
trn
AI1T
Setup desired value entry
5 V
5 V
nCr
Motor nominal current
3.6 A
3.5
ItH
Thermal motor nominal current
3.6A
3.5
nSP
Motor rated speed
1390 U/min
1400 U/min
Ctt Motor
control
model
PErF
Std
COS Cosinus
Phi
0.76
0.77
SLP Slip
compensation
7%
100%
rrS anticlockwise
L2H
nO
PS2
2 preselection frequency-allocation.
L3H
nO
SP2
2. preselection frequency
50 Hz
10 Hz
Table 2: M99E-230V-3,6kW-DS parameter setting for frequency converted
Parameter set ATV12 (M99-DS_pro)
V1.0.3
Code
Description
750 W 4 pol.
Factory setting
ACC Run-up
time
2.0 s
3.0 s
dEC Starting
time
1.0 s
3.0 s
LSP Low
frequency
30.0 Hz
0 Hz
tFr
Maximum Output frequency
70.0 Hz
60.0 Hz
HSP High
frequency
70.0 Hz
50.0 oder 60.0 Hz
nPr
Motor power rating
0.75 kW
0.75 kW
TCT
Model 2- wire-control
trn
trn
AI1T
Setup desired value entry
10 V
5 V
nCr
Motor nominal current
3.6 A
3.5
ItH
Thermal motor nominal current
3.6A
3.5
nSP
Motor rated speed
1390 U/min
1400 U/min
Ctt Motor
control
model
PErF
Std
COS Cosinus
Phi
0.76
0.77
SLP Slip
compensation
7%
100%
rrS anticlockwise
L2H
nO
PS2
2 preselection frequency-allocation.
L3H
nO
SP2
2. preselection frequency
50 Hz
10 Hz
PS3
3 preselection frequency-allocation.
L4H
nO
SP3
3. preselection frequency
50 Hz
10 Hz
Table 3: M99E-230V-3,6kW-DS-Pro parameter setting for frequency converter