23
Wybron's IT equipment (Coloram IT, CXI IT, Eclipse Shutter IT, and Eclipse Iris IT) is
equipped with a series of sensors that can relay a wealth of information to Infogate. These
sensors can detect everything from light, voltage, and current, to fan speed and even
gelstring frame color information.
So while RDM equipment will allow identification and remote addressing, IT equipment can
give more specific status information and warn of potential problems, possibly averting
failures in the middle of a show. If the status of a device indicates any problem, Infogate
displays an alert with the nature of the problem and its exact location. Troubleshooting is
now done in a fraction of the time.
Infotrace provides the ability to:
• Automate the setup of DMX addresses – no more manual setting of DIP switches
• Proactively check the condition of equipment before, during and after a show
• Track lamp duty cycles to predict lamp failures before they happen
• Predict maintenance on equipment
Sensors
• Aperture Light Sensor: Detects if the fixture's lamp is on.
• Voltage Sensor: Reports the head voltage level.
• Timers: Tracks how many hours unit has been in operation since last maintenance cycle.
• Fan RPM Sensor: RPM sensor on fan.
• Self-Test Mode: Moves the dowser fins without a DMX input command.
Alert Warnings
Fan Stopped Warning
High Motor Current Warning during initialization
Init Fail
Low Voltage Alert
Low Voltage Unit Shutdown
Features
Self-Test Mode: Moves the dowser fins without a DMX input command.
Reverse Polarity Protection: Auto shutdown if dowser plugs into a Coloram II power supply.
Summary of Contents for 87250
Page 1: ...1 Eclipse IT Iris User Manual ...
Page 3: ...3 Safety Notice SAVE THESE INSTRUCTIONS ...
Page 25: ...25 2 1 3 4 5 6 8 11 10 9 7 ...
Page 26: ...26 13 14 15 12 19 18 17 16 21 20 27 26 25 24 23 22 ...
Page 27: ...27 28 34 33 32 31 30 29 ...
Page 29: ...29 Revision History Version Author Date Description 2 0 John Tabor 2 10 09 Model numbers ...