“VOLTAGE DROPPED
BELOW 13V
UNIT SHUTDOWN”
Unit has automatically shut down because operating voltage has dropped
below 13 volts for more than one second. The Eclipse cannot operate properly
below 15VDC. The voltage typically drops this low if the Eclipse IT Iris cable is
too long — the head-feet limit has been exceeded. The cable must be
shortened to solve this problem.
MOTOR ALERT
1.
“MOTOR IS
OPERATING AT A HI
CURRENT LEVEL”
High current level at the fin motors may indicate an ususually high level of
friction at the motor. Please check Eclipse motor for possible maintenance or
replacement.
FAN ALERT
1.
“FAN IS NOT
OPERATING
PROPERLY”
Check Eclipse fan for any maintenance needs.
RESET ALERT
Clears existing alert from display screen when you press
SELECT
(unless problem still
currently exists).
MULTIPLE ALERTS
1.
Press
SELECT
to read the first alert.
2.
Press
SELECT
to read the details of the first alert.
3.
Press
BACK
to view the second alert.
4.
Press
SELECT
to view details of the second alert.
5.
Press
BACK
to check if there any additional alerts, then repeat steps four and five
until all alerts have been read.
6.
Once all alerts have been read, use the
d
key to move the selection box to the
“RESET ALL ALERTS” command.
7.
Press
SELECT
to clear all alerts, except those that currently exist as problems.
DMX Address
1.
Use the arrow buttons to select the desired DMX address.
2.
Press
SELECT
to activate the displayed DMX address.
Settings
Summary of Contents for 87250
Page 1: ...1 Eclipse IT Iris User Manual ...
Page 3: ...3 Safety Notice SAVE THESE INSTRUCTIONS ...
Page 25: ...25 2 1 3 4 5 6 8 11 10 9 7 ...
Page 26: ...26 13 14 15 12 19 18 17 16 21 20 27 26 25 24 23 22 ...
Page 27: ...27 28 34 33 32 31 30 29 ...
Page 29: ...29 Revision History Version Author Date Description 2 0 John Tabor 2 10 09 Model numbers ...