User Manual
10
y
Charge when power on
-
Power on when using the batteries, then connect the camera with adapter, the red indicator will flicker slowly.
-
(
When charging Press button
to power off the red indicator will flicker slowly
-
After charging, green indicator flickers slowly.
Note:
y
The batteries cannot be taken out of the camera in the power-on charging process.
y
Defect: When there is a circuit break or damage in the thermal resistor which detects the charging temperature of
the batteries, the batteries cannot be charged.
Buttons Introduction
There are three functional buttons of
GUIDE® EASIR-9
(
From left to right, they are
,
and
)
and a trigger button “T”.
Power on /off the camera
The input voltage is 12V
,
keep button
depressed for more than 3 seconds to power on. When powering off,
keep the button
depressed until the switch off bar runs fully. To release the button
at any time before
the switch off bar runs fully to leave the power off state.
Focus and Image zoom
On the non-menu mode, rotate the lens manually until you get a focused image. When doing manually focus, please
keep the camera steady, to ensure high accuracy.
On the non-menu mode, press the button to zoom in the image to x2, with the current magnification shown at the up
left corner of the screen.
Quick function
On the non-function mode, press button
shortly to enter key functional menu, the following info will be
displayed on the screen
:
Visual Spot
Fusion
y
Press
to enter spot analysis mode
Summary of Contents for GUIDE EasIR-9
Page 25: ...User Manual 22 ...