The following describes the data tags displayed in the
RAFT
Status
Menu:
BACK
Press
to return back to the previous
Status Menu screen.
REF COPY
Press
to copy the RAFT Reference Weld
data from one schedule to another.
R MEASURE
Press
to turn the R Measure Mode ON
or OFF.
REF OFF
Press
to turn the Reference Mode ON or
OFF.
NOTE:
The data displayed in this menu may vary depending upon the cus-
tomers application requirements. For application specific information,
consult the weld control firmware manual.
SEQ#
Sequence (schedule) number
Mode
AdaptQ Mode ON/OFF (0=OFF, 1=ON)
ref h
Total heat of the Reference Weld
h
Total heat
exp cy
The number of milliseconds since the
beginning of the weld at which expulsion
was detected
PI
Process Integrity
ref e
Total energy of the Reference Weld
Summary of Contents for DEP 300s
Page 1: ...USER MANUAL DEP 300s Q06905 Weld Control Communications...
Page 4: ...M035030_V2 1 Q06905 12 2016 1 of 8...
Page 10: ...M035030_V2 1 Q06905 12 2016 7 of 8 NOTES...
Page 11: ...M035030_V2 1 Q06905 12 2016 8 of 8...
Page 21: ...M035030 V2 0 Q06905 07 2017 18 of 18...
Page 59: ...M035030 V2 0 Q06905 07 2017 56 of 104 D Press Sch E Enter Schedule Number F Press ENTER...
Page 63: ...M035030 V2 0 Q06905 07 2017 60 of 104 D Press Sch E Enter Schedule Number F Press ENTER...
Page 64: ...M035030 V2 0 Q06905 07 2017 61 of 104 G Press MORE H Press COPY...
Page 129: ...M035030 V2 0 Q06905 07 2017 126 of 126...
Page 136: ...M035030 V2 0 Q06905 07 2017 133 of 134 Notes...
Page 137: ...134 of 134 24775 CRESTVIEW COURT FARMINGTON HILLS MI USA 48335 PHONE 1 248 477 3900...