APPLIANCE INFORMATION
Greenstar FS CDi
ErP
6720818079 (2016/04)
7
2.3
Product data on energy consumption
The following product data satisfy the requirements of the EU Regulations No. 811/2013, No. 812/2013, No. 813/2013 and No. 814/2013
supplementing Directive 2010/30/EU.
Product data
Symbol
Unit
7731600102
7731600103
7731600104
7731600105
Product type
–
–
30CDi Regular
ErP
NG
30CDi Regular
ErP
LPG
42CDi Regular
ErP
NG
42CDi Regular
ErP
LPG
Condensing boiler
–
–
Yes
Yes
Yes
Yes
Rated heat output
P
rated
kW
30
30
41
41
Seasonal space heating energy efficiency
η
s
%
92
92
92
92
Energy efficiency class
–
–
A
A
A
A
Useful heat output
At rated heat output and high temperature
regime
1)
1) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C flow temperature at heater outlet.
P
4
kW
30.0
30.0
40.8
40.8
At 30 % of rated heat output and low
temperature regime
2)
2) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
P
1
kW
10.0
10.0
13.6
13.6
Useful efficiency
At rated heat output and high temperature
regime
1)
η
4
%
88.5
88.5
88.1
88.1
At 30% of rated heat output and low
temperature regime
2)
η
1
%
97.1
97.1
97.0
97.0
Auxiliary electricity consumption
At full load
el
max
kW
0.042
0.042
0.073
0.073
At part load
el
min
kW
0.017
0.017
0.016
0.016
In standby mode
P
SB
kW
0.004
0.004
0.004
0.004
Other items
Standby heat loss
P
stby
kW
0.053
0.053
0.053
0.053
Ignition burner power consumption
P
ign
kW
0
0
0
0
Emissions of nitrogen oxides
NOx
mg/kWh
23
23
57
57
Sound power level, indoors
L
WA
dB(A)
53
53
54
54
Table 5 Product data for energy consumption