INSTALLATION
Greenstar FS CDi
ErP
6720818079 (2016/04)
21
All dimensions in mm
Fig. 21 Boiler flue outlet positions
4.3
Flue measuring and cutting
Flue length guide
Access to combustion chamber for flue installation
▶ Grip the outer sides of the front panel [1] pull off the ball catches [2]
and lift away from the retaining lugs [3].
▶ Remove the retaining screw [4] to swing control panel assembly [5]
outwards to its full extent.
▶ Release four screws [6] to remove the inner case cover [7].
Fig. 22 Access for flue connection
4.4
Condensate, gas and water connections
CONDENSATE CONNECTION:
Refer to figures 23 and 24.
The condensate pump [7] fills up and periodically discharges through
the flexible condensate pipe [8] between 200mm to 4500mm from
floor level. After this point the condensate flows, due to gravity, down
the 21.5mm plastic pipe to the outlet.
▶ Fit the bayonet connector on the end of the condensate waste pipe to
the condensate pump. Push down and rotate clockwise until the
connector is locked.
▶ Route and secure condensate waste pipe [8] with clips supplied to
prevent kinking or restriction.
▶ Cut off any excess pipe [8].
▶ Fit the condensate waste pipe [8] to adaptor [11] and secure with
clip [10].
▶ Connect adaptor [11] to 21.5mm plastic pipe and terminate
appropriately as described in section 3.4.
NOTICE:
Flue installation
▶ Refer to the Flue Kit Installation instructions
provided with your flue kit to correctly install the flue
with this Floor standing boiler
NOTICE:
FLUE LENGTH
▶ Do not exceed the maximum straight length for a
horizontal or vertical flue or a 60mm plume
management system (if used) as stated in the
relevant Installation, Commissioning and Servicing
Instructions manual or addendum.
Cutting the flue to an exact measurement is not normally
required as the telescopic flue terminal can allow for
some adjustment.
Maximum effective flue lengths FS 30/42
ErP
L max. (mm)
60/100 horizontal
4 000
60/100 vertical
6 400
80/125 horizontal
13 000
80/125 vertical
15 000
Table 10 Maximum flue lengths
6720648568-53.1W
o
Z
Y
X
X
1
4
Z
Y
3
3
2
123
123
267
123
743
143
Flue length range (mm)
Cut
Number of extensions
140
1)
- 265
1) The flue is cut to a minimum of 130mm the flue connector adds the additional
10mm.
YES
None
310 - 530
NO
None
530 - 750
NO
None
750 - 1260
YES
1
1260 - 1480
NO
1
1480 - 2210
YES
2
2210 - 2430
NO
2
2430 - 3160
YES
3
3160 - 3380
NO
3
3380 - 4000
YES
4
Table 11 Flue extension guidance up to 4000mm