Technical data
DESCRIPTION
UNITS
Natural Gas
L.P.G
FS 30CDi
FS 42CDi
FS 30CDi
FS 42CDi
Central Heating
Max. rated heat output net 40/30°C
kW
32.1
43.7
32.1
43.7
Max. rated heat output net 50/30°C
kW
31.8
43.3
31.8
43.3
Max. rated heat output net 80/60°C
kW
30
40.8
30
40.8
Max. rated heat input net
kW
30.9
42
30.9
42
Min. rated heat output net 40/30°C
kW
8.6
10.8
11.6
13.5
Min. rated heat output net 50/30°C
kW
8.6
10.7
11.4
13.4
Min. rated heat output net 80/60°C
kW
7.7
9.6
10.5
12.0
Min. rated heat input net
kW
8
10
10.8
12.5
Max. flow temperature
°C
88
88
88
88
Max. permissible operating pressure
bar
2.65
2.65
2.65
2.65
Gas flow rate - Max. 10 minutes from lighting
*The Gas Rate provided assumes the accepted Natural Gas averaged CV of 1040Btu/ft3 = 38.76Mj/m3
*
Natural gas (network gas)
m
3
/h
3.19
4.29
-
-
Test gas (G20 ) 1014Btu/ft
3
= 37.78MJ/m
3
m
3
/h
3.27
4.4
-
-
Propane Gas (LPG)
kg/h
-
-
2.3
3.3
Gas supply pressure
Natural Gas G20
mb
20
20
-
-
LPG (Propane) Gas G31
mb
-
-
37
37
Flue
Flue Gas Temp. 80/60°C, rated min. load
°C
67/55
67/55
67/55
67/55
Flue Gas Temp. 40/30°C, rated min. load
°C
43/32
43/32
43/32
43/32
CO
2
level at max. rated heat output
%
9.4
9.4
10.8
10.8
CO
2
level at min. rated heat output
%
8.6
9.0
10.4
10.4
NOx - classification
class
5
5
5
5
Condensate
Max. condensation rate
l/h
2.7
3.7
2.7
3.7
pH value, approx.
4.8
4.8
4.8
4.8
Electrical
- Class 1 equipment (must be earthed)
Electrical power supply voltage
AC...V
230
230
230
230
Frequency
Hz
50
50
50
50
Max. power consumption (without pump)
W
60
80
60
80
General Data
SEDBUK (Band A) 2005
%
90.5
90.3
91.9
91.1
SEDBUK 2009
%
88.9
88.8
89.9
89.8
Appliance protection rating
IP
X4D
X4D
X4D
X4D
Permissible ambient temperatures
°C
0-50
0-50
0-50
0-50
Nominal capacity of appliance
Itr
3.75
3.75
3.75
3.75
Weight (excluding packaging)
kg
55.1
55.1
55.1
55.1
Table 4 Technical data