LEMCOM EtherNet/IP™ - User manual
Technical specifications
COVAL - LMEIP-UK-D-1155UM0067
40/42
10.4
Standards and Regulations
LEMCOM has been developed in accordance with the following standards:
-
EN61000-6-4/A1: 2007/2010
-
EN61000-6-2: 2005
Test standard
Description
Test result
CISPR 16-2-3
Radiated disturbance measurements
Class A
CISPR 16-2-1
CISPR 14-1
Conducted disturbance measurements (power supply
access)
Class A
CISPR 22
Conducted disturbance measurements
(communication and network access)
Class A
IEC / EN 61000-4-2
Electrostatic discharges (ESD)
Criterion B
IEC/EN 61000-4-3
Immunity to radiated interference
Criterion A
ENV 50204
Criterion A
IEC/EN 61000-4-4
Electrical Fast Transient / Burst Immunity Test
Criterion B
IEC/EN 61000-4-5
Lightning and industrial surges
Criterion B
IEC/EN 61000-4-6
Immunity to conducted interference
Criterion A
IEC/EN 61000-4-8
Immunity to magnetic fields
Criterion A
IEC/EN 61000-4-11
Voltage dips, short interruptions and voltage
variations immunity tests’
Criterion A/B
NF EN 60068-2-6
(2008)
Vibration resistance
5g, 10 to 150 Hz, 1 hr /
axes (x, y, z)
NF EN 62262
IK07 test - Protection against mechanical impacts
Impact energy: 2 joules,
500g weight, height:
40cm
NF EN 60068-2-27
(2009)
Shock resistance
10g, 11 ms, Half-Sine
Shock Pulse, 6 shocks
per axis (x, y, z)
/
Humidity test
+40°C, 95% RH, 24 hrs
/
Temperature test
72 hrs, 1°C / minute, 24
hrs at 0°C, +25°C and
+50°C