10.1
General characteristics
The LEMCOM vacuum pump must be used with power supply units that provide a
Protective Extra Low Voltage (PELV) and with an isolation of the supply voltage according
to EN60204.
10.2
Current consumption table
The LEMCOM structure implies that all vacuum generators connected together on the COVAL bus
are electrically supplied by the same power source. The following consumption table has to be taken
into account when the required power supply wattage and amperage is calculated.
Number of
modules
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Maximum
current
draw (mA)
24V supply
150 250 350
450
550
650 750
850
950
1050 1150 1250 1350
1450 1550 1650
Table 23 - Current consumption of a LEMCOM island