LEMCOM EtherNet/IP™ - User manual
EtherNet/IP™
COVAL - LMEIP-UK-D-1155UM0067
34/42
8.9.9
Configuration instance 160
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
↓ ISLAND SETTINGS ↓
Bytes 0-15
Byte 0 : L1 gripping threshold for master module
Byte 1 : L1 gripping threshold for SM1
…
Byte 15 : L1 gripping threshold for SM15
Bytes 16-31
Byte 16 : h1 gripping hysteresis for master module
Byte 17 : h1 gripping hysteresis for SM1
…
Byte 31 : h1 gripping hysteresis for SM15
Bytes 32-47
Byte 32 : L2 regulation threshold for master module
Byte 33 : L2 regulation threshold for SM1
…
Byte 47 : L2 regulation threshold for SM15
Bytes 48-63
Byte 48 : h2 regulation hysteresis for master module
Byte 49 : h2 regulation hysteresis for SM1
…
Byte 63 : h2 regulation hysteresis for SM15
Byte 64
ASC SM7
ASC SM6
ASC SM5
ASC SM4
ASC SM3
ASC SM2
ASC SM1
ASC
Master
Module
Byte 65
ASC SM15
ASC SM14
ASC SM13
ASC SM12
ASC SM11
ASC SM10
ASC SM9
ASC SM8
Byte 66
DIAG ECO
SM7
DIAG ECO
SM6
DIAG ECO
SM5
DIAG ECO
SM4
DIAG ECO
SM3
DIAG ECO
SM2
DIAG ECO
SM1
DIAG ECO
Master
Module
Byte 67
DIAG ECO
SM15
DIAG ECO
SM14
DIAG ECO
SM13
DIAG ECO
SM12
DIAG ECO
SM11
DIAG ECO
SM10
DIAG ECO
SM9
DIAG ECO
SM8
Bytes 68-83
Byte 68 : Maximum bounces number for master module
Byte 69 : Maximum bounces number for SM1
…
Byte 83 : Maximum bounces number for SM15
Bytes 84-99
Byte 84 : DIAG ECO analysis time (second) for master module
Byte 85 : DIAG ECO analysis time for SM1
…
Byte 99 : DIAG ECO analysis time for SM15
Byte 100
AUTO
BLOW SM7
AUTO
BLOW SM6
AUTO
BLOW SM5
AUTO
BLOW SM4
AUTO
BLOW SM3
AUTO
BLOW SM2
AUTO
BLOW SM1
AUTO
BLOW
Master
Module
Byte 101
AUTO
BLOW
SM15
AUTO
BLOW
SM14
AUTO
BLOW
SM13
AUTO
BLOW
SM12
AUTO
BLOW
SM11
AUTO
BLOW
SM10
AUTO
BLOW SM9
AUTO
BLOW SM8
Bytes 102-
133
Byte 102 : Auto blow off duration (ms) for master module (1 to 9999 ms)
– Least Significant Byte (LSB)
Byte 103 : Auto blow off duration (ms) for master module
– Most Significant Byte (MSB)
Byte 104 : Auto blow off duration (ms) for SM1
– Least Significant Byte (LSB)
Byte 105 : Auto blow off duration (ms) for SM1
– Most Significant Byte (MSB)
…
Byte 132 : Auto blow off duration (ms) for SM15
– Least Significant Byte (LSB)
Byte 133 : Auto blow off duration (ms) for SM15
– Most Significant Byte (MSB)
Bytes 134-
149
Byte 134 : Valves status (in case of communication loss) for master module
Byte 135 : Valves status for SM1
…
Byte 149 : Valves status for SM15
Bytes 150-
165
Byte 150 : Customer LED mode (blue LED) for master module
Byte 151 : Customer LED mode for SM1
…
Byte 165 : Customer LED mode for SM15
Table 21 - Data mapping - Configuration instance 160