Troubleshooting Guide
Electrical Problems
Troubleshooting Guide
doc092506
4-3
4
4.2
Electrical Problems
PROBLEM
CAUSE
SOLUTION
Up/down Excessively Slow.
Vertical wear pads too tight.
Adjust pads.
Up/down belt loose.
Adjust belt to be as loose as
possible without slipping
Up/down Or Power Feed
Motors Do Not Work.
Worn/dirty contacts in drum
switch.
Replace switch or remove con-
trol panel cover and clean con-
tacts.
Bad key switch.
Replace key switch.
Circuit breaker.
Burned-out motor.
Replace motor.
Bad connection on battery
post or loose wire.
Check for loose wire or termi-
nal connections.
Up/down motor relay dam-
aged.
Have a qualified electrician
replace the relay.
Up/down motor is damaged.
Have a qualified electrician
replace the up/down motor.
One phase lacks.
Check circuit breakers in the
connectors.
Motor thermal protector
started to work.
Let the motor cool abd then
reset the thermal protector.
Speed switch circuit over-
loaded.
Turn off the power bad let the
motor cool. Turn the power
back on.
Power feed is overheated.
Turn off the power abd let the
motor cool. Turn the power
back on.
Short circuit in speed switch
motor system.
Have a qualified electrician
remove the short circuit.
Up/Down Or Power Feed
Switches Remain Engaged
When Switch Is Released.
Worn or dirty contacts in drum
switch.
Manually move the power feed
or up/down switch back to
neutral or "off" position.
Replace drum switch or
remove control panel cover
and clean and lubricate con-
tacts NOTE: Use only contact
grease supplied by
Wood-Mizer.
Drum switch spring broken.
Manually move the power feed
or up/down switch back to
neutral or "off" position.
Replace drum switch spring.