Sawmill Operation
Startup Configuration
4
4-10
WMdoc072919
Sawmill Operation
Startup Configuration
Accuset controls on new sawmills are configured at the factory.
IMPORTANT!
If you have installed or replaced the control, you must
configure the control before operating the Accuset. Follow the proce-
dures below
in the order they are listed
.
Configuration Menu 1
1.
Press the Up button while in Manual Mode to enter Configuration Menu 1.
See Figure 4-7.
ADJUST THE GRADIENT
If the Accuset is factory-installed, the Gradient Setting is already set to match the gradient
of the transducer sensor (labeled "GRD" on the sensor). If the Accuset has been installed
in the field, the transducer replaced, or the Accuset control has been reset to Factory Set-
tings, the Gradient Setting should be adjusted.
2.
Press the button labeled “Calib. Head.”
3.
Press the button labeled “Adjust Gradient.”
FIG. 4-7
6 - 3/4
CONFIGURATION MENU 1
Calib. Head
Save
Set Kerf
Other
LX0046
Push UP button to enter
Configuration Menu 1
Auto-Down
Manual
Auto-Up
Pattern