Maintenance and Alignment
Safety Devices Inspection (Only CE Version)
Maintenance and Alignment
EGdoc020420
5-16
5
should not be possible to restart the motor/engine until the E-STOP button is released.
3. Inspecting the Safety Switch Circuit - Blade Cover (Gas Edger)
Start the main engine;
Open the cover;
The main engine should stop;
Try to start the engine. It should not be possible to start the engine.
Close the cover.
Inspecting the Safety Switch Circuit - Blade Cover (Electric Edger)
Start the main motor;
Try to open the cover;
It should not be possible to open the cover when the motor is running.
FIG. 5-15
Outfeed Table
E-STOP