Maintenance and Alignment
Safety Devices Inspection (Only CE Version)
5
5-15
EGdoc020420
Maintenance and Alignment
5.11 Safety Devices Inspection (Only CE
1
Version)
EG100 Edger Safety Devices Inspection
Before beginning a shift, inspect the following safety devices of the EG100 edger:
E-Stop button circuit - control box
E-Stop button circuit - outfeed table
Safety switch circuit - cover
1. Inspecting the E-Stop Button Circuit - Control Box
Start the main motor/engine,
Press the emergency stop button located on the control box. The motor/engine should stop.
It should not be possible to restart the motor/engine until the E-STOP button is released.
2. Inspecting the E-Stop Button Circuit - Outfeed Table
Start the main motor/engine;
Press the emergency stop button located on the outfeed table. The motor/engine should stop. It
1.
Marking of products sold within European Economic Area
FIG. 5-14
Control Box
E-Stop
Button
Outfeed Table
E-Stop Button
Blade Cover