Planning Information
For ease of installation, Wolf recommends using 33"
(838)
wide cabinets with 30"
(762)
gas cooktops and 39"
(991)
cabinets with 36"
(914)
cooktops.
ELECTRICAL REQUIREMENTS
GAS SUPPLY REQUIREMENTS
A gas supply line of
3
/
4
"
(19)
rigid pipe must be provided
to the cooktop. If local codes permit, a certified, 3'
(.9 m)
long,
1
/
2
"
(13)
or
3
/
4
"
(19)
ID flexible metal appliance con-
nector is recommended to connect the units
1
/
2
" NPT
female inlet to the gas supply line.
Wolf natural gas cooktops will function up to an altitude
of 10,250'
(3124 m)
without adjustment and LP gas
cooktops will function up to 8,600'
(2621 m)
. If the installa-
tion exceeds these elevations, contact your authorized
Wolf dealer for a high altitude conversion kit.
Electrical Requirements
GAS COOKTOPS
Electrical Supply
120 V AC, 60 Hz
Service
15 amp dedicated circuit
Receptacle
3-prong grounding-type
Power Cord
6'
(1.8)
Gas Supply Pressure
NATURAL GAS
Gas Supply Pressure
5"
(12.5 mb)
WC
Min Line Pressure
7"
(17.5 mb)
WC
Max Pressure to Regulator
14"
(34.9 mb)
WC, .5 psi
(3.5 kPa)
LP GAS
Gas Supply Pressure
10"
(25 mb)
WC
Min Line Pressure
11"
(27.4 mb)
WC
Max Pressure to Regulator
14"
(34.9 mb)
WC, .5 psi
(3.5 kPa)