Wolf Dual Fuel Ranges
63
wolfappliance.com/specs
Planning Information
Available in four widths, Wolf dual fuel ranges are
designed to fit a 30"
(762)
, 36"
(914)
, 48"
(1219)
or 60
1
/
4
"
(1530)
opening.
IMPORTANT NOTE:
When installing against a combustible
surface, a minimum 10"
(254)
riser is required for a 36"
(914)
dual fuel range with charbroiler or griddle and all
48"
(1219)
and 60"
(1524)
models. Follow all minimum clear-
ances to combustible surfaces shown in the installation
illustrations on the following pages.
It is recommended that you use a Wolf pro ventilation
hood or hood liner with the dual fuel range. If the range is
to be installed without ventilation, a 36"
(914)
minimum
clearance, 44"
(1118)
for charbroiler, from countertop to
combustible materials above the range is required. Refer
to page 105 for pro ventilation.
Oven Specifications
INTERIOR CAPACITY
CU FT
(L)
18"
(457)
Oven
2.5
(71)
30"
(762)
Oven
4.5
(127)
36"
(914)
Oven
5.4
(153)
INTERIOR DIMENSIONS
W
H
D
18"
(457)
Oven
14"
(356)
16
1
/
2
"
(419)
19"
(483)
30"
(762)
Oven
25"
(635)
16
1
/
2
"
(419)
19"
(483)
36"
(914)
Oven
30"
(762)
16
1
/
2
"
(419)
19"
(483)
Burner Rating
Btu
(kW)
Btu
(kW)
SURFACE BURNERS
SIMMER
HIGH
Large (3 or 5)
950
(.3)
15,000
(4.4)
Small (1)
325
(.1)
9,200
(2.7)
OPTIONAL FEATURES
NATURAL
LP
Infrared Charbroiler
16,000
(4.7)
16,000
(4.7)
Infrared Griddle
15,000
(4.4)
13,000
(3.8)
Double Griddle
30,000
(8.8)
26,000
(7.6)
French Top
15,000
(4.4)
15,000
(4.4)
ELECTRICAL REQUIREMENTS
Wolf dual fuel ranges have a terminal block that allows for
a 3-wire or 4-wire installation.
GAS SUPPLY REQUIREMENTS
A gas supply line of
3
/
4
"
(19)
rigid pipe must be provided to
the range. If local codes permit, a certified, 3'
(.9 m)
long,
1
/
2
"
(13)
or
3
/
4
"
(19)
ID flexible metal appliance connector is
recommended to connect the units
1
/
2
" NPT male inlet to
the gas supply line.
Wolf natural gas ranges will function up to an altitude of
10,250'
(3124 m)
without adjustment and LP gas ranges will
function up to 8,600'
(2621 m)
. If the installation exceeds
these elevations, contact your authorized Wolf dealer for
a high altitude conversion kit.
Gas Supply Pressure
NATURAL GAS
Gas Supply Pressure
5"
(12.5 mb)
WC
Min Line Pressure
7"
(17.5 mb)
WC
Max Pressure to Regulator
14"
(34.9 mb)
WC, .5 psi
(3.5 kPa)
LP GAS
Gas Supply Pressure
10"
(25 mb)
WC
Min Line Pressure
11"
(27.4 mb)
WC
Max Pressure to Regulator
14"
(34.9 mb)
WC, .5 psi
(3.5 kPa)
Electrical Requirements
SINGLE OVEN RANGES
Electrical Supply
Grounded, 240/208 V AC, 60 Hz
Service
30 amp dedicated circuit
Total Amps
21
DOUBLE OVEN RANGES
Electrical Supply
Grounded, 240/208 V AC, 60 Hz
Service
50 amp dedicated circuit
Total Amps
42.5
Summary of Contents for SO30F/S