W415-2968 / B / 04.30.21
EN
8
rough framing
single-sided recessed
!
WARNING
•
When using DHM, power and A/V cables being run through the enclosure must maintain a 7” clearance from the top of
the collector box and a 3.5” clearance from all other ducting and venting components. Conduit is also required, but high
temperature conduit is recommended.
•
When using termination plates, you must also not have any wiring above the termination plate discharge air openings.
Ref
38” models
50” models
62” models
74” models
K
39 15/16” (101.4cm)
E
18” for single-sided | 16 3 1/6” for see-thru
F
53 13/16” (136.7cm)
65 13/16” (167.2cm)
77 13/16” (197.6cm)
89 13/16” (228.1cm)
J
Optional - Appliance does not need to be elevated above fl oor
L
84” (213.4cm)
91” (231.1cm)
Q
4 1/8”
M
3 3/4” (78mm)
* Opening
must
be centered in enclosure on appliance. Dimensions represent fi nished sizes and where applicable should be
adjusted to include fi nish material thickness.
minimum framing
Finish framing
must
be built
after appliance has been placed
in its fi nal position and venting
connected.
note:
The Linear series requires a
minimum enclosure height,
as illustrated (dimension L),
measured from the bottom of
the appliance. For temperature
requirements, this area must be
left unobstructed. Some venting
confi gurations that require more
vertical rise will require a larger
enclosure to provide minimum
vertical clearance between vent
pipes and combustibles.
K
R
E
F
J
L
M
Q
3/4” plywood