80
User Manual WMF espresso
Messages and instructions | Troubleshooting
Error pattern
Action instructions
9562/9563
Too much
ground coffee in
the portafilter
(left / right)
Check whether the portafilter was emptied after the
last brewing cycle
Empty the portafilter
Check whether the correct sieve is loaded in the
portafilter
Make sure that the portafilter is emptied each time
a beverage is prepared
Clean the ground coffee chute
Clean the distributor sieve regularly
Distributor sieve rinsing
w
page 62
Clean the brewing group manually
w
Care
w
Clean the brewing group manually, page 64
In the recipe for the beverage that was last dispensed,
reduce the ground coffee quantity by 0.1 grams
If error not remedied
Switch off the coffee machine
Call WMF Service
9880
Check the time and
set the clock
Check the time and set the clock
Switch the coffee machine off and on again
If error not remedied
Call WMF Service
F161
Less than minimum
required flow rate
Clean the portafilter and the brewing sieve
Open water supply valve
F164
Less than minimum
hot water dispensing
flow rate
Switch off the coffee machine
Remove the hot water spout and clean the screen
Caution. Hot liquids.
Open water supply valve