4.9.1
Save Session
Arm SAVE SESSION by pressing [GLOBAL] in Memory Mode. The display will
show ‘S’ followed by the currently selected slot. Use ENCODER 1 to select a
new slot if desired. Press [GLOBAL] again to save the session.
4.9.2
Load Session at End of Bar
The normal loading procedure will load the session at the end of the next bar,
or the end of the pattern if it occurs before the next bar. First select the session
you would like to load using the [MATRIX] or ENCODER 1. Arm LOAD by pressing
[TEMPO]. The step display will show ‘L’ followed by the selected slot. Press
[TEMPO] again to load.
!
Pressing [RESET] will force any pending Load operation
to happen immediately even if no clock is present. If the display
reads ‘BSY’, no force load will take place.
Turn ENCODER 1 to
select a session. Turn
while LOAD is armed to
load a single variation.
When the desired session
is selected press [GLOBAL]
to arm SAVE. Press again
to save.
Turn
ENCODER 2
to
select a project. Each
project contains 64
sessions.
Use the [MATRIX]
to directly select a
session.
When the desired
session is selected press
[TEMPO] to arm LOAD.
Press again to load.
22
4.9
MEMORY
Metron’s memory can contain up to 512 sessions, addressed in banks of
64 across 8 projects. The memory interface is accessed by pressing the
[MEMORY] button.