The remote access is possible by SSH and FTP service.
SSH Connection
The device can be accessed through SSH
connection, when it is available on its IP
address
–
by a terminal utility (e.g.
putty)
–
at
the
192.168.127.1:22
(port nr. 22
–
LAN
interface).
Accept (Yes) the Putty or other SSH
terminal’s Security Alert of the RSA2 key
of the device to allow and trust the
connection
–
by security reasons.
SSH login data:
Login
:
root
Password
:
wmrpwdM2M
Now you are logged in, at the
OpenWrt
®
’s command line.
Here you can use Linux
commands or using scripts or
the
uci
commands on the
device. (Check chapter 4.8 for
more information about the
UCI
®
.)
6.8 Device Manager
®
settings
Our Device Manager
®
application can be used for the remote management of the load control box
(WM-E LCB device), which is used for the remote maintenance and reconfiguration of the device in
addition to the continuous monitoring of the operating characteristics (network access, field
strength, runtime, QoS).