Options
: A complex parameter with
Baudrate
sel
Stopbit
defi
Databits
defi
Parity
type
-
Baudrate
(default is
9600
bps for the RS485) can be defined between 300 bps and
115 200 bps.
-
Stopbit
value
can be 1 or 2
-
Databits
value
can be 7 or 8
-
Parity
value can be EVEN, ODD or NONE
Examples:
For standard speed 7E1 mode use this command:
9600 1STOPBIT 7DATABIT EVEN
For lower speed 8N1 mode use this one:
2400 1STOPBIT 8DATABIT NONE
Important!
Note that maximum 115 200 baud speed rate can be used wheather of the
configuration options.
But, we offer to use the standard 9600 baud or 2400 baud
speed rate for receiving or transmitting data without character / data loss.
The incoming RS485 data are not stored locally, they will be transparently transmitted
from the device through the cellular network.
Note, that you should add the specified RS485 port number to the
Firewall
rules
(
Network / Firewall
menu), otherwise the router will not receive any data.
You can also specify additional members, such as
hardware flow control
with the
RTSCTS
, which can be turned off with the "
-
" prefix. A
space
character must be placed
between members.
If you have modified the settings, save by
Save & Apply
button.
You can connect an
IIoT IO/RS485 concentrator
to collect input signals, readout status
of digital inputs:
https://m2mserver.com/en/product/iiot-io-data-concentrator-16di/
Important!
In case of Modbus / RS485 interface connector you can use the router with the RS485
settings as a transparent Modbus gateway without any change.
If you have special request on Modbus, indicate or declare your interest with details by
ordering. We can provide a customized command line interface operated special
modbus program for the needs.