W5500S2E serial to Ethernet module
W5500S2E user manual
26
RESET (Save and restart the module)
Command format
Parameters
Usage
AT+RESET=<parameter>
Module password; Default: admin
Set
Response
OK\r\n
Example
Command: AT+RESET=admin\r\n
Response: OK\r\n
Exact password must be input to execute this command
It will save the current settings
Restart the module so that the setting is effective
The module will be in preset “Start mode” after reset.
EXIT (Save and exit command mode)
Command format
Parameters
Usage
AT+EXIT
Nil
Execute
Response
OK\r\n
Example
Command: AT+EXIT\r\n
Response: OK\r\n
It will save the current settings
Restart the module and make the settings take effect
Module will be entered into “Data pass-through mode”
SAVE (Save settings)
Command format
Parameters
Usage
AT+SAVE
Nil
Execute
Response
OK\r\n
Example
Command: AT+SAVE\r\n
Response: OK\r\n
It will save the current settings
Make the settings take effect
After execute this command, the module will be still in “AT command mode”. This is for save the
settings in the AT data transfer command mode.
Note: This command is supported by firmware version 2.3 and above.