7
Maintenance and repair
➤
➤
Set-up work for production changes, as well as cleaning and mainte-
nance work, may only be performed by trained operators.
➤
➤
Maintenance and repair work may only be performed by trained service
personnel.
➤
➤
Prior to beginning this work, the spray equipment must be shut down and
pressure released. Read and follow the instructions in the user’s manual
for the spray equipment.
➤
➤
Trigger the spray gun briefly to release pressure prior to disconnecting it
from the spray unit. Proceed carefully! Residual pressure may be pres-
ent!
➤
➤
After completion of maintenance work, the function of all safety devices
and spray gun must be checked.
Regularly cleansing and servicing prolongs the life-span of the
high pressure spray gun. For a general cleansing we offer a
professional service in our company.
7.1 Lubrication
➤
O-ring, needle guidance, needle seal, as well as lever bearing need to be
lubricated regularly with silicone-free oil and/or silicone-free grease.
7.2 Cleaning
➤
➤
Flush vigorous immediately after use or longer work interruptions with
solvent corresponding to the spraying material.
Flushing is complete when clean solvent comes out of the gun.
➤
➤
Never place the spray gun in a solvent bath.