Adjusting the flat stream
With flat stream control (s. assembly details, Pos. 4) the mixing of the atom-
izing air can be adjusted.
clockwise
less air - minimal atomization
counter clockwise
more air - maximal atomization
Adjusting the round stream
Through the mixing of additonal air (round stream regulation, s. assembly
details, Pos. 5), the flat stream can be reshaped to a round stream.
clockwise
less air - flat stream
counter clockwise
more air - round stream
Regulating the spring pressure
The trigger spring is adjustable (s. assembly details, Pos. 6)
➤
➤
Adjust the spring pressure/preload according to the fluid pressure.
turn screw clockwise
high spring preload (250 bar, 3626 psi)
turn screw counter clockwise
low spring preload (80 bar, 1160 psi)
For pressures between 80 and 250 bar (1160-3626 psi), select an appropriate
position in between.
Adjusting the direction of the Flat Stream
The position of the air cap und the spray tip determine the direction of the
spray pattern.
1.
Interrupt the air supply to the entire spray unit.
2.
Trigger the spray gun to release the pressure.
3.
Lock the spray gun (safety lever horizontal).
Translation of the original operation manual