Translation of the original operation manual
DUOMIX 230
23
DM230_BAoDB_en_1307 · rs
Unit description
3.4.3 External mixing unit
No. Description
1
Lever to open and close the return
flow. During spraying and flushing
operation the return flow is closed
and is opened for material circulation
or to relieve pressure.
2
Lever to switch the operating mode
“Spraying” on and off.
3 + 4 Levers to switch the operating mode
“Flushing” on and off.
Fig. 18: External mixing unit
1
2
3
4
With these levers you can set the operating modes “Circulation”, “Spraying”
und “Flushing” as follows:
Circulate
Spray
Flush
Fig. 19: Circulate
see
Fig. 18
Fig. 20: Flush
Position of levers:
Operating mode Lever 1
Lever 2
Lever 3
Lever 4
Circulate
ON
OFF
OFF
OFF
Spray
OFF
ON
OFF
OFF
Flush
OFF
OFF
ON / OFF
1)
ON / OFF
1)
1)
Alternately open and close the flushing levers several times during flushing,
to ensure that each component is separately flushed. Finally flush with both
levers in flushing position.