Translation of the original operation manual
DUOMIX 230
37
DM230_BAoDB_en_1307 · rs
Maintenance
6.2 Maintenance plan
The information in the maintenance plan are recommendations. The inter-
vals may vary in dependence on the condition of materials used and outer
influences.
Interval
Activity
before each start-up
Check the lubricant level, top up if necessary
1 x per week
Checking and adjusting the fog oiler
1 x per week
Checking and cleaning the water separator
every 50 operating hours
Check release agent of the main pump for
material residues
depending on the type and
cleanliness of the material or
with every material change
Clean the filter elements in the high pressure
filters
depending on the saturation
of the granulate
Dry the moisture filter (if present)
6.3 Maintenance unit
The maintenance unit prevents condensation water and dirt particles from
entering into the unit and supplies the compressed air with oil for lubrication of
moving parts.
The maintenance unit is equipped with the following maintenance facilities:
Fig. 33: Maintenance unit
1
3
4
5
6
7
8
2
No. Designation
1
Fog oiler adjusting screw
2
Inspection glass
3
Oil filler plug
4
Slide
5
Oil tank
6
Water separator
7
Drain valve
8
Drain hose
6.3.1 Checking the lubricant level in the fog oiler
Operation of the unit must only be started if the oil reservoir of the fog oiler
contains a sufficient amount of oil for the air motors.
In case of high humidity you should use an antifreeze agent for lubrication,
to avoid icing of the air motor
.
Summary of Contents for Duomix 230