17
WT-1011RC IP65 GSM Remote Controller And Alarm System
WT-1011RC IP65 – USER MANUAL – Rev.1.6 – Technical Support:
COPYRIGHT ©2010 WITURA CORPORATION SDN BHD
The Input Alert Message can be edited and programmed up to 40 characters long. You
can change the displayed text by sending the following commands by SMS message to
the unit.
Note: Only support normal abc/ABC English text, no special characters.
Text Command:
*STO[N]#XXXXX…
N stands for number 1 - 2 of Input
XXXXX… stands for the display text that you want to program
Example:
If you want the alert message to display “Garage Closed!” when input 1 triggered; you
would send the following SMS message to the unit.
*STO1#Garage Closed!
Example of Returned Message:
#STRALM1:<Garage Closed!>
An alert message will be sent when the increment of alarm counter reaches the alert
value (Default: 500). It is possible to set the alert value up to maximum value of
65,535 times. To set the counter alert value of input, you can send the following
commands by SMS message to the unit.
Text Command:
*COA[N]#XXXXX
N stands for number 1 - 2 of Input
XXXXX stands for 5 digits value: The number of times
Example:
Assume that you want it to send a counter alert message each time the input 1 has
triggered for 5 times, you would send the following SMS message to the unit.
*COA1#00005
Example of Returned Message:
#COA1=00005
5.5.4 Editing the Input Alert Message For (When Input returned to Normal)
5.5.5 Setting the Counter Alert Value For Inputs