Troubleshooting and eliminating faults
INTORQ | BA 14.0210 | 12/2016
47
Brake does not release
Incorrect microswitch wiring
Check the wiring of the microswitch and correct it.
Microswitch incorrectly set
Replace the complete stator and make a complaint about
the setting of the microswitch to the manufacturer.
Air gap too big
Adjust the air gap (
26)
Measure the rotor thickness and compare against the min-
imum rotor thickness (
rotor.
Rotor cannot rotate freely Wrong setting of manual
release
Check the dimension "s+s
L
" with the brake energized. The
dimension must be the same on both sides. Correct if
required.
Air gap "s
L
" too small
Check air gap "s
L
" and adjust it if necessary (
Rotor thickness too small
Rotor has not been replaced
in time
Replace the rotor (
Voltage not zero during
functional test (
Incorrect microswitch wiring
Check and correct the wiring of the microswitch.
Microswitch defective or
incorrectly set
Replace the complete stator and send the complete
stator to the manufacturer.
Voltage too high
Brake voltage does not match
the rectifier
Adjust rectifier and brake voltage to each other.
Voltage too low
Brake voltage does not match
the rectifier
Adjust rectifier and brake voltage to each other.
AC voltage is not mains
voltage
Fuse is missing or defective
Select a connection with proper fusing.
Incorrect microswitch wiring
Check and correct the wiring of the microswitch.
Microswitch defective or
incorrectly set
Replace the complete stator and return the defective com-
plete stator to the manufacturer.
Fault
Cause
Remedy
Summary of Contents for WSG-TB.3 series
Page 29: ......
Page 30: ......
Page 31: ......
Page 33: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 95: ...Notes INTORQ BA 14 0197 04 2016 48 Notes...
Page 144: ...Notes INTORQ BA 14 0210 12 2016 48 Notes...
Page 145: ...Notes INTORQ BA 14 0210 12 2016 49...
Page 146: ...Notes INTORQ BA 14 0210 12 2016 50...
Page 147: ......