5.3.3 Demounting IP20
The demounting of the drive can be done by pressing down and pulling the drive out of the
top-hat rail.
5.3.4 Installation space IP20
The central variant of the drive amplifier is designed for installation in the control cabinet.
5.3.5 Environmental conditions for vibration/shock IP20
The drive amplifier fulfills the following specifications:
−
Vibration according to DIN EN 60068-2-6:2008
o
Frequency range 10 Hz – 150 Hz
o
Acceleration: 1 g
−
Shock according to DIN EN 60068-2-27:2010
o
Shock form: Semi-sinusoidal
o
Acceleration: 15 g
o
Duration of the shock: 11 ms