6.4.12 X8: Power supply
−
The logic supply is galvanically isolated from the intermediate voltage.
−
The safety input STO is galvanically isolated from the intermediate voltage.
Figure
Pin
no.
Signal
name
Function
Input/
output
1
VCC24
Logic 24 VDC
Input
2
STO
Safe Torque off input
Input
3
GND
Logic reference ground
Input
4
STO GND STO reference ground
Input
5
BRAKE+
Holding brake +
Output
6
BRAKE-
Holding brake -
Output
7
TEMP+
Motor temperature
Input
8
N.C.
9
TEMP-
Motor temperature
sensor -
Input
Plug type at cable: Phoenix Contact FK-MC 0,5/ 9-ST-2,5
Permissible conductor cross-section: 0,25 .. 0,5 mm²
Stripping length: 8 mm
Connection
Properties
Unit
Minimum
value
Nominal
value
Maximum
value
VCC24
Voltage
V DC
22
24
26
Current
mA DC
200
STO
Voltage
V DC
22
24
26
Current
mA DC
80
BRAKE+/-
Voltage
V DC
24
Current
A DC
0,8