Technical Description
TABLE OF CONTENTS:
1. General information ........................................................................................ 2
2. Terms and definitions according to the norms ............................................... 2
3. Symbols meaning ............................................................................................ 2
4. Build description and technical specification ................................................ 2
4.1. Application and designation ................................................................ 2
4.2. Safety guidelines ................................................................................... 2
5. Installation guidelines ..................................................................................... 2
6. Required installation conditions ..................................................................... 2
7. Installation instructions .................................................................................... 3
7.1. Installation sequence ............................................................................. 3
7.2. Photocells circuit diagram ..................................................................... 3
7.3. Bell-push circuit diagram ....................................................................... 3
7.4. El3Q radio receiver circuit diagram ..................................................... 3
7.5. Drive installation errors .......................................................................... 3
8. Environment protection ................................................................................... 3
9. Dismantling the drive ....................................................................................... 4
10. Operation issues ............................................................................................. 4
11. Technical parameters ...................................................................................... 4
12. Door instruction manual .................................................................................. 4
13. Drive adjustment .............................................................................................. 5
13.1. Overload adjustment ............................................................................. 5
14. Controller ......................................................................................................... 5
14.1. The intended use and operation principle ........................................... 5
14.2. Controller installation sequence ........................................................... 5
14.3. Controller programming ........................................................................ 5
15. Routine maintenance instructions ................................................................... 6
16. Warranty terms ............................................................................................... 6
17. The equipment of the MIDO drive ................................................................. 7
18. FAQ .................................................................................................................. 8
[A000001]
1. GENERAL INFORMATION
The door can be installed and adjusted by at least a COMPETENT person.
[A000019] This Assembly Instruction is intended for professional installers or
other competent persons. It provides necessary information on safe installation
of the drive unit.
[A000020] The drive and its components have to be installed in line with the
drive Installation & Operation Manual supplied by „WIŚNIOWSKI” ltd. Only
original fixing parts, supplied with the drive, may be used to install the drive.
Read this manual before proceeding with the installation works. Read this man-
ual carefully and follow the guidelines in it. Correct drive operation to a large
degree depends on its correct installation.
[A000021] Drawings may differ in build details. When necessary, such details
are presented in separate drawings. This instruction provides the necessary in-
formation on a safe installation, usage and maintenance of the drive.
When proceeding with the installation, follow the safety rules on the following:
installation works, fitting works, and usage of electric tools applicable to the
installation method selected. Current norms, regulations and the construction
documentation should be followed too. In maintenance protect the drive from
plaster, cement and gypsum spalls likely to leave stains.
[A000022] Assembly and Operating Instruction is intended for the drive owner.
When the installation is complete, this manual should be issued to the owner. It
should be kept carefully and be protected against damage. No elements of the
drive may be modified or removed. Doing so may influence its safe operation.
Changing drive subassemblies is forbidden.
[A000042] When installing the drive, follow the guidelines of “WIŚNIOWSKI”
sp. z o.o. sp. k., the manufacturer of both the drive and the accessories. In con-
necting the drive, only original subassemblies may be used.
[D000136]
This book covers installation of the drive with standard
and optional accessories. Standard and optional equipment rang-
es are listed in the commercial offer.
[A000023]
WARNING: Read this manual carefully and
follow the instructions. It provides the necessary infor-
mation on a safe installation, usage and maintenance of
the drive. Keep this instruction with due care.
[A000037]
2. TERMS AND DEFINITIONS ACCORDING TO THE NORMS
Meaning of safety pictograms used in this book:
Important
- a sign to draw your attention.
Information
- a sign meaning an important bit of information.
Reference
- a sign referring you to another place in this book.
Professional installer
- a competent person or business unit who/which of-
fers door installation and enhancement services (as in EN 12635).
Competent person
- a person with a relevant training record, possessing
skills based on his/her knowledge and experience, and familiar with the nec-
essary instructions to proceed with the installation properly and safely (as in
EN 12635).
Owner
- a natural or legal person entitled to dispose of the door and responsi-
ble for its operation and usage (as in EN 12635).
Report book
– a book with main data of a particular door and blanks for
inspections, tests and maintenance entries, as well as repairs and modifications
reports (as in EN 12635+A1).
[D000137]
3. SYMBOLS MEANING
Rs – unlocking in sectional doors
Ru – unlocking in up-and-over doors
Pw – white wire
Pr – red wire
Pg– green wire
Pb – brown wire
Py – yellow wire
[A000052]
- option
- manual
- automatic
[D000138]
4. BUILD DESCRIPTION AND TECHNICAL SPECIFICATION
The drive makes a set with a slide rail of a relevant length which is necessary
for its correct operation. It is mounted on the end of a steel slide rail. The rail is
equipped with a driving chain which drives a catch. The catch is integrated with
a door. The operator drives the door via an arm fastened to the chain holder
from one side, and to the door leaf top part on the other side. The drive is pro-
tected with overload switches; when the door leaf meets resistance on the way,
the drive will stop and reverse.
[D000139]
4.1. APPLICATION AND DESIGNATION
The drive is used to open automatic sectional and up-and-over garage doors,
with dimensional limits specified in the commercial offer, as well as operation
time limits and technical specifications from this instruction. The drive is intended
for dry rooms, and it may not be applied outdoors.
[B000004]
4.2. SAFETY GUIDELINES
Minimum safety levels provided in the door closing edge as required by
PN-EN 13241-1.
Door activation
method
Usage
Trained door
operators (private
premises)
Trained door
operators (public
premises)
Not trained
door operators
(public pre-
mises)
Deadman control with
the view of the door
(the Totmann version)
Push-button control
without electrical
latching
Key-switch control
without electrical
latching
Unacceptable
Pulse control with the
view of the door
(the Automatik version)
Pulse control without the
view of the door
(the Automatik version)
Automatic control
(the Automatik version
– automatic closing)
– safety bar - obligatory
– photocells barrier - obligatory
– photocells barrier - optional
[A000024]
5. INSTALLATION GUIDELINES
Read these guidelines before proceeding with installing and starting up the
drive. Follow the drive installation and usage guidelines for a long and efficient
usage. The order of the installation steps must be followed too.
[A000025]
6.
REQUIRED INSTALLATION CONDITIONS
The drive should be applied and operated in line with its designation. A selec-
tion of the operator must be based on the way the door is driven.
[B000026] The room where the drive fitting is planned should be finished
completely (plastered walls, finished floor). It should be also dry and free of
any harmful chemicals.