7
7
Vilhelmsborgvej 15
DK-7700 Thisted
Tel.: (+45) 97990800
Loosen the lock nut. The rotation speed is adjusted by turning
the screw. When turning to the left, the probe will move faster.
When turning to the right, the probe will slow down. The
adjusting screw must be set to 50 r.p.m.
Press the button down, and turn it counter-clockwise. The
button will come up. Start the motor with max. r.p.m. Press
the main valve, and the probe will rotate.
Press the button down. Turn it to the left so that it stays down.
Loosen the lock nut. Adjust with a 6 mm hex key. Pressure
will rise when turning to the right. Lower the pressure by
turning to the left.
Adjusting the rotation speed
Adjusting the pressure of the probe
Depending on the vehicle’s weight and the kind of soil, the
pressure must be between 10 and 30 bar. Read the pressure
on this manometer, which only is for reading the pressure of
the probe.