Adjust the pressure by using a 2 mm hex key. Pressure will rise
when turning the key to the right. For lowering the pressure, the
key must be turned to the left. The pressure must be adjusted so
that the soil sampler stands firm and stable on the ground.
7. Adjusting the hydraulics
Adjusting the main pressure
Start the motor with max. RPM. Press the main valve. The
manometer must show 140 bar.
This valve is for adjusting the main pressure. The main pressure
is pre-set ex works on 140 bar. It must only be adjusted after
signing a written agreement with Wintex Agro ApS.
Fuse:
There is a 7.5 amp fuse for current control in the control box
.
Dismount the plug.
Adjusting the pressure of the soil sampler towards the ground