Rinse aid and detergent
9
5.3 Suction tube with level control
Caution
Only use the suction tube with sufficiently stable containers. Narrow and tall containers can
tip if the suction tube is pulled.
Do not place the suction tube for the rinse aid in the detergent container or vice versa.
Do not pull unnecessarily on the suction hose or main power cable, as this may lead to a
defect.
As an option, with your machine you may have one or more suction tubes. The suction tube is already con-
nected to the machine.
Figure 1:
Suction tube for detergent
Transparent suction hose
Black cap
Figure 2:
Suction tube for rinse aid
Blue suction hose
Blue cap
Figure 1
Figure 2
Servicing and maintenance
Rinse the suction tube at every container change under running water. Re-
move crystallised detergent residue.
Ensure that both vent holes (a) in the caps are open.
Put the suction tube back into the container. Slide the cap downwards until
the container opening is closed.
5.4 Changing the detergent product
Caution
Mixing different detergents can lead to efflorescence that can lead to a failure of the deter-
gent dosing device. This is applicable even if the new detergent is from the same manufac-
turer.
The dosing tubes and the detergent dosing device must be thoroughly rinsed with water
before the new detergent is used.
A new detergent product usually requires a new setting of the detergent dosing device. Assign the re-
quired work to an authorised service technician to attain good cleaning results.
If this is not done, the warranty and product liability of Winterhalter Gastronom GmbH expires.