External dosing devices
24
16.2 Electrical connection
IMPORTANT
maximum current drain at the transfer strip: 0.5 A.
Connect the external dosing device to the 5-pin pug.
Terminals (arranged from top to bottom)
Terminal
Voltage is on
Condition
Restriction
Setting
L1
continuous voltage
N
Rinse
(O18)
parallel to solenoid valve (O7)
while the machine is filling
during rinsing
a)
c)
Wash
(O20)
while the circulating pump is
running
a)
c), d), e)
Fill / Water
(O17)
while the machine is filling
a), b)
parallel to solenoid valve (O7)
while the machine is filling
during rinsing
a)
c)
a) only with the hood closed
b) minimum water level in the tank
c) not in the self-cleaning programme
d) not while the machine is filling
The settings
and
control when a voltage is present at the Fill/Water and Rinse terminals.
Connecting an external detergent dosing device
Example 1:
Hose pump with time-delay
relay and fixed output
Example 2:
Hose pump with adjustable
output
Example 3:
Hose pump with fixed output
(e. g. ESP 166, ESP 166C,
SP 166Z)
Connect to “Wash” terminal.
Set time-delay relay on the
dosing device.
Connect to “Fill/Water” ter-
minal.
Set
.
Set output on the dosing
device.
Connect to “Fill/Water” termi-
nal.
Set
.
Set both potentiometers to
maximum.
Set dosing amount on the
machine.
If the capacity is not equal to
166 ml/min, set P706 (see
service instructions).
Connecting an external rinse aid dosing device
Example 1:
Hose pump with adjustable
output
Example 2:
Hose pump with fixed output
(16 ml/min) (e.g. SP 16K )
Connect to “Rinse” terminal.
Set
.
Set output on the dosing
device.
Connect to “Rinse” terminal.
Set
.
Set potentiometer to maxi-
mum.
Set dosing amount on the
machine.
Summary of Contents for PT 500
Page 1: ...Rack pass through dishwasher PT 500 Operating instructions ...
Page 2: ......
Page 24: ...Electrical connection 22 15 3 Connection diagram ...