4.11 Making Tubing Connections

(Tubing is not Performance Tested or Certified by NSF)

1. Measure 3/4” from the end of each remaining piece of tubing (faucet end and inlet

end) and mark with a pencil (Check for roundness, smoothness, cuts, nicks, flat spots
and sharp edges.)

2. Push the tubing firmly into each fitting on the manifold until the line is flush with the

fitting collar. (If the tubing is removed, re-cut the end, measure, mark and re-insert).
Tubing must be fully inserted to avoid leaks (To remove tubing, depress and hold white
collet; pull tubing out to remove.)

4. Pull out slightly on tubing to ensure a good seal. Do no pull too hard or it may damage

related parts.

5. Install the other end of the tubing from the inlet side of the manifold to the feed water

adapter.

6. Insert plastic tab to ensure quick connect fitting cannot come as done.

CORRECT

end of tubing round and smooth.

with no cuts, nicks or flat spots

t

n

e

m

e

g

a

g

n

e

 l

a

it

r

a

p

 t

c

e

r

r

o

c

n

I

d

e

t

c

e

n

n

o

c

 

d

n

a

 t

u

c

 

y

lt

c

e

r

r

o

c

 

g

n

i

b

u

T

correct full 3/4”

INCORRECT

4.12 Connect Water Lines

To connect the water lines, begin by taking the plastic supply line form the angle stop or saddle
valve and firmly connect it to the left most quick connect the on the top of the Fincel system
labeled “In”, Push the water line in completely and gently pull back out until it stops. Then
insert a blue locking clip to secure it.
Take the second feed line and repeat the process with the middle quick connect labeled "Out".
Leave the auxiliary cap in if you’re not using it to supply another faucet or appliance.
Take the free end of the second “Out” feed line and firmly attach it to the quick connect at the
base of the drinking faucet stem. Assure it’s properly connected like before and attach a blue
locking clip

Filtered Water

Faucet

Hot

Sink

Cold

Nut

Nut-tighten

if necessary

use to connect

tubing

Bottom

bolt

Handle

Valve

Insert

1/4”tubing
Ferrule

(Plastic)

Saddle Valve Connections

<Figure 4.10.3>

<Figure 4.11.1>

<Figure 4.11.5>

<Figure 4.11.2-4>

<Figure 4.10.4>

To Disconnect Tubing :

1. Remove plastic tab from fitting
2. Push the collet inward and hold with a finger while pulling the tubing out. Make sure

the collet is pushed evenly on all sides.  If only one side is pushed the tubing will not be
able to be removed.

collet (depress to remove tubing)

tubing

IMPORTANT:

Remove plastic plugs from water line inserts.

Summary of Contents for Finecel FCSPU1

Page 1: ...2013 02 28 Please contact your dealer for questions regarding your product and to purchase WINIX Replacement Filters...

Page 2: ...anty Filters which are expendable are not covered by the warranty TO OBTAIN WARRANTY PARTS SIMPLY CALL 1 877 MY WINIX 699 4649 Monday Friday 8 am 5 pm CST for assistance This warranty applies only whi...

Page 3: ...l the system Follow your local codes if they may differ with guides in this manual The Water Filtration System works on water pressures of 20 psi minimum to 100 psi maximum If your house water pressur...

Page 4: ...before starting installation Read and follow the instructions provided with any tools listed here Tape Measure Marking pen Adjustable Wrench Phillips Slotted Screwdrivers Leveler Cutter Drill Drill B...

Page 5: ...pipe 4 5 Determine The Installation Location Determine the location where you intend to install the drinking water faucet Make sure it is far enough away from the main faucet so that they don t interf...

Page 6: ...unter top 4 Connect flexible hoses to supply stops Base Cover Gasket Mounting Surface Washer Fixing Nut 1 Remove plastic panel on back at perforation with slotted screwdriver 3 Place unit above bracke...

Page 7: ...lve will be placed on 4 Turn the valve handle all the way out counter clockwise Be sure the piercing pin does not stick out beyond the seal 5 Place the saddle valve on the cold water pipe over the cle...

Page 8: ...the water lines begin by taking the plastic supply line form the angle stop or saddle valve and firmly connect it to the left most quick connect the on the top of the Fincel system labeled In Push th...

Page 9: ...amily with clean healthy and great tasting drinking water 1 Unscrew to remove the aerator wire screen and washer from the end of faucet 2 Position the Diverter Valve onto the faucet and hand tighten t...