7.0 TROUBLESHOOTING

Problem: Chlorine taste and/or odor in the filtered water.

Cause:

The level of chlorine in your water supply exceeds maximum limits, and has

destroyed the Ultra Filtration membrane.

Correction:

If the water supply contains more than 2.0 ppm of chlorine, additional

filtering of the water supply to the UF is needed. Correct this condition before doing
maintenance on the Ultra Filtration system.

Cause:

The pre filter is no longer reducing chlorine from the water supply.

Correction:

Replace the pre filter, post filter and Ultra Filtration membrane cartridges. 

Problem: No water or decreased water flow.

Cause:

Pre-Filter A is clogged.

Correction:

Replace Pre-Filter A.

Cause:

Flow through the microbiological purifying filter will decrease and eventually clog

when exposed to an excess of microbiological loading materials in the water.
This failsafe feature reduces the chance of product use beyond its intended life, and will
shut down the filter when it is exposed to contaminated water.

Correction:

Replace all filter cartridges.

Problem: Taste and/or Odor.

Cause:

Filter cartridges exhausted.

Correction:

Replace all filter cartridges.

Cause:

System contaminated.

Correction:

Sanitize system. Call location of purchase for instructions.

Problem: FCSPU1 LED indicator light does not function after battery change.

Cause:

Battery dead.

Correction:

Replace with new battery.

Cause:

Battery installed incorrectly.

Correction:

Install battery correctly.

Problem: Water leaks at push connect fittings.

Cause:

Tubing not pushed in all the way. 

Correction:

Push tubing in all the way into fittings.

Cause:

Tubing not cut square.

Correction:

Cut tubing square.

Cause:

Tubing nicked.

Correction:

Remove nicked portion, reinsert tubing into fitting.

Cause:

Outer tubing surface not smooth. 

Correction:

Remove rough portion, reinsert tubing into fitting.

Problem: Tubing does not connect to water filtration system.

Cause:

Black plugs are still connected to the unit.

Correction:

Remove black plugs and insert tubing into fitting.

Summary of Contents for Finecel FCSPU1

Page 1: ...2013 02 28 Please contact your dealer for questions regarding your product and to purchase WINIX Replacement Filters...

Page 2: ...anty Filters which are expendable are not covered by the warranty TO OBTAIN WARRANTY PARTS SIMPLY CALL 1 877 MY WINIX 699 4649 Monday Friday 8 am 5 pm CST for assistance This warranty applies only whi...

Page 3: ...l the system Follow your local codes if they may differ with guides in this manual The Water Filtration System works on water pressures of 20 psi minimum to 100 psi maximum If your house water pressur...

Page 4: ...before starting installation Read and follow the instructions provided with any tools listed here Tape Measure Marking pen Adjustable Wrench Phillips Slotted Screwdrivers Leveler Cutter Drill Drill B...

Page 5: ...pipe 4 5 Determine The Installation Location Determine the location where you intend to install the drinking water faucet Make sure it is far enough away from the main faucet so that they don t interf...

Page 6: ...unter top 4 Connect flexible hoses to supply stops Base Cover Gasket Mounting Surface Washer Fixing Nut 1 Remove plastic panel on back at perforation with slotted screwdriver 3 Place unit above bracke...

Page 7: ...lve will be placed on 4 Turn the valve handle all the way out counter clockwise Be sure the piercing pin does not stick out beyond the seal 5 Place the saddle valve on the cold water pipe over the cle...

Page 8: ...the water lines begin by taking the plastic supply line form the angle stop or saddle valve and firmly connect it to the left most quick connect the on the top of the Fincel system labeled In Push th...

Page 9: ...amily with clean healthy and great tasting drinking water 1 Unscrew to remove the aerator wire screen and washer from the end of faucet 2 Position the Diverter Valve onto the faucet and hand tighten t...

Page 10: ...cartridge to left clockwise until Insert arrow aligns with the arrow on the system manifold Pull straight down to remove filter 2 Dispose of filter cartridge properly 3 Install new cartridge by aligni...

Page 11: ...set after replacing filter Battery Indicator When the timer reaches approximately 18 months of use it will flash At this time it is recommended to replace battery When the batteries are installed for...

Page 12: ...oduct use beyond its intended life and will shut down the filter when it is exposed to contaminated water Correction Replace all filter cartridges Problem Taste and or Odor Cause Filter cartridges exh...

Reviews: