background image

18

17

5.0 FILTER CARTRIDGE

5.1 Carbon Filter Cartridge Life

Taste and Odor, and Microbiological Purifying Cartridges:

Taste and odor, and

microbiological cartridges contain 

activated carbon

. When new, a small amount of harmless

carbon particles may be present in the filtered water. Open the faucet and flush for
2 minutes. It is recommended to 

replace carbon filter cartridges every six months or

400 gallons

of use. There are several variables that determine how long a cartridge will last.

These include:

1. How much water you use, and
2. How much sediment, taste and/or odor, or other unwanted substance, is in the water.

Use the following information as a guide. However, no matter which type of cartridge you are
using, you will know it is time to replace them when you first notice the return of the unwanted
sediment, taste and/or odor in your water, or when the flow diminishes or stops.

WINIX Water Filtration System model FCSPU1 with replacement filters SPCF1 and SPUF1
conforms to NSF/ANSI 42 and 53 for the specific performance claims as verified and
substantiated by test data. The rated capacity for this system is 400 gallons (1513 liters) at a
rated service flow of 0.5 gallons per minute.

5.2 UF Cartridge Life

5.3 Filter Cartridge Replacement

1. Turn filter cartridge to left (clockwise) until “Insert” arrow aligns with the arrow on the

system manifold.  Pull straight down to remove filter.*

2. Dispose of filter cartridge properly.
3. Install new cartridge by aligning “Insert” arrow with the arrow on the manifold. Turn filter to

right (counter clockwise) until “Lock” arrow is aligned with the  arrow on the manifold.

4. Turn water and system faucet on to check for leaks. If leaking occurs, reinstall filter and check

for proper arrow alignment.

5. Flush filter unit for at least 2 minutes prior to use.
* Turn water off at plumbing connection first. While not necessary, it can reduce potential

leaking

Filter

A

Filter

B

Filter

C

Head

Filter cartridge

Turn filter cartridge

to the right to

attach to head manifold

Turn filter cartridge

to the left to

remove from manifold

<Figure 5.3.1>

The rated capacity for the UF Filter Cartridge is 1200 gallons or 18 months at a rated flow of 

0.5 gallons per minute.  This filter is responsible for a filtration process that removes:

microbiological pollutants, heavy metals, and many other pollutants.

IMPORTANT:  The UF Filter Cartridge must be operate when water is between 

33° and 100° F.

WARNING: The UF Filter Cartridge will be damaged if frozen.  The UF Filter Cartridge

must be kept above temperatures of 32°F (0°C). Failure to do so may cause the 

UF Filter Cartridge to dry, freeze, become damaged, and will void all warranties.  Operating

a damaged system may lead to personal injury and/or physical harm.

Summary of Contents for Finecel FCSPU1

Page 1: ...2013 02 28 Please contact your dealer for questions regarding your product and to purchase WINIX Replacement Filters...

Page 2: ...anty Filters which are expendable are not covered by the warranty TO OBTAIN WARRANTY PARTS SIMPLY CALL 1 877 MY WINIX 699 4649 Monday Friday 8 am 5 pm CST for assistance This warranty applies only whi...

Page 3: ...l the system Follow your local codes if they may differ with guides in this manual The Water Filtration System works on water pressures of 20 psi minimum to 100 psi maximum If your house water pressur...

Page 4: ...before starting installation Read and follow the instructions provided with any tools listed here Tape Measure Marking pen Adjustable Wrench Phillips Slotted Screwdrivers Leveler Cutter Drill Drill B...

Page 5: ...pipe 4 5 Determine The Installation Location Determine the location where you intend to install the drinking water faucet Make sure it is far enough away from the main faucet so that they don t interf...

Page 6: ...unter top 4 Connect flexible hoses to supply stops Base Cover Gasket Mounting Surface Washer Fixing Nut 1 Remove plastic panel on back at perforation with slotted screwdriver 3 Place unit above bracke...

Page 7: ...lve will be placed on 4 Turn the valve handle all the way out counter clockwise Be sure the piercing pin does not stick out beyond the seal 5 Place the saddle valve on the cold water pipe over the cle...

Page 8: ...the water lines begin by taking the plastic supply line form the angle stop or saddle valve and firmly connect it to the left most quick connect the on the top of the Fincel system labeled In Push th...

Page 9: ...amily with clean healthy and great tasting drinking water 1 Unscrew to remove the aerator wire screen and washer from the end of faucet 2 Position the Diverter Valve onto the faucet and hand tighten t...

Page 10: ...cartridge to left clockwise until Insert arrow aligns with the arrow on the system manifold Pull straight down to remove filter 2 Dispose of filter cartridge properly 3 Install new cartridge by aligni...

Page 11: ...set after replacing filter Battery Indicator When the timer reaches approximately 18 months of use it will flash At this time it is recommended to replace battery When the batteries are installed for...

Page 12: ...oduct use beyond its intended life and will shut down the filter when it is exposed to contaminated water Correction Replace all filter cartridges Problem Taste and or Odor Cause Filter cartridges exh...

Reviews: