LP4 USER MANUAL
-
33 -
Sensor
settings
Sensor type:
Use Current Printer Setting (by previous setting)
Reflective sensor
(Recommend)
Transmissive sensor
Start Position Offset: (recommend to input number when the
printing position has a little bit shift up or shift down)
If selected, user can fill up how many dots to adjust the start printing
position.
7.5.3 Sensor Calibration
Sensor
Calibration
Settings
Please run the sensor calibration after the label material has
been changed.
Each time of sensor calibration will feed 15 inches long label
for usage.
Label Type: Label with Gaps, Label with Marks, Continuous
(same setting from Media Settings page)
Sensor: Use Current Printer Settings, Reflective sensor,
Transmissive sensor (same setting from Media Settings page)
Auto Detection
(Recommend)
The printer will start to run the sensor calibration
automatically and will feed 15 inches long label out.
Manual Set
Sensor Strength: Normal, High Sensitive, Ultra Sensitive
Reflective Sensor Value: 15 (default value is 15)
Transmissive Sensor Value: 15 (default value is 15)
The value range of sensor is from 5 to 100, less value is more
sensitive
7.5.4 Options
Item
Description
After Print
Use Current Printer Settings: see previous setting
Remove tick option would have below several options
Summary of Contents for LP4 Series
Page 1: ...LP423A LP433A USER MANUAL User Manual LP4 series Issue Date 2016 11 14 Version 2 0...
Page 8: ...LP4 USER MANUAL 8 2 2 Appearance Figure 1 Front View Figure 2 Rear View...
Page 9: ...LP4 USER MANUAL 9 Figure 3 Inside View...
Page 16: ...LP4 USER MANUAL 16 4 1 Ribbon Installation Path...
Page 19: ...LP4 USER MANUAL 19 5 1 Label installation path...
Page 51: ...LP4 USER MANUAL 51 8 5 1 Operating procedures Standalone operating procedures diagram...