SAFETY

IMPORTANT SAFETY INSTRUCTIONS

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

SAFETY DEFINITIONS

DANGER

Indicates an imminently hazardous situation 

which, if not avoided, will result in death or 

serious injury. 

WARNING

Indicates a potentially hazardous situation 

which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury. It may also be used to alert 

against unsafe practices.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to the 

State of California to cause cancer, birth defects or 

other reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

DANGER: ELECTRICAL SHOCK 

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated 

by a responsible person.

 

A. Do not allow anyone to operate the generator 

   without 

proper 

instruction.

 

B. Guard against electric shock.

 

C. Avoid contact with live terminals or receptacles.

 

D. Use extreme care if operating this unit in rain or 

   snow.

 

E. Use only three-pronged grounded receptacles 

   and 

extension 

cords.

 

F. Be sure the unit is properly grounded for your 

   application.

DANGER: DEADLY EXHAUST GAS

Exhaust fumes from any gasoline engine contain 

carbon monoxide, an invisible, odorless and deadly gas 

that must be mixed with fresh air.

 

A. Operate only in well ventilated areas.

 

B. Never operate indoors including attached 

   garages

 

C. Never operate the unit in such a way as to allow 

      exhaust gases to seep back into closed rooms 

      (i.e. through windows, walls, floors).

WARNING: FIRE HAZARD

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

 

A. Do not refuel when the engine is running or hot.

 

B. Keep fuel containers out of reach of children.

 

C. Do not smoke or use open flame near the 

      generator set or fuel tank.

 

D. Keep a fire extinguisher nearby and know its 

      proper use. Fire extinguishers rated ABC by 

   NFPA 

are 

appropriate.

 

E. Store fuel only in an approved container, and 

      only in a well ventilated area.

 

F. Follow local codes for closeness to combustible 

   material.

CAUTION: PERSONAL INJURY

The muffler becomes very hot during operation and 

for a period after the unit has been turned off. Do not 

touch the muffler until it has completely cooled off.

CAUTION: NOISE HAZARD

Excessive noise is not only tiring, but continual 

exposure can lead to loss of hearing.

 

A. Use hearing protection when working around 

      this equipment for long periods of time.

 

B. Keep your neighbors in mind when using this 

   equipment.

CAUTION

Keep the generator and surrounding area clean.

 

A. Remove all grease, ice, snow or materials that 

   create 

      slippery conditions around the unit.

 

B. Remove any rags or other materials that could 

      create a potential fire hazard.

 

C. Carefully clean up any gas or oil spills before 

   starting 

the 

unit.

CAUTION

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

 

A. Use only factory approved repair parts.

 

B. Do not work on this equipment when fatigued.

 

C. Never remove the protective guards, covers, or 

      receptacle panels while the engine is running.

 

D. Use extreme caution when working on electrical 

      components. High output voltage from this 

      equipment can cause serious injury or death.

 

E. Always avoid hot mufflers, exhaust manifolds, 

      and engine parts. They can cause severe burns 

   instantly.

 

F. The use of the engine-generator set must comply 

      with all national, state, and local codes.

Summary of Contents for WL16000HE-03/A

Page 1: ...ontact us concerning this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DATE _________________________________________ DEALER NAME ___________________________________________ DEALER PHONE ________________________________________ www wincogen com 16200 031 ...

Page 2: ...LEANING TROUBLESHOOTING TABLE 18 WIRING DIAGRAM 19 CA EVAPORATIVE EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator Keep this manual available for future reference USING ...

Page 3: ...t must be mixed with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into closed rooms i e through windows walls floors WARNING FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B K...

Page 4: ... low variable load Derate the running watts 20 for these types of loads GENERATOR Generator Manufacturer Mecc Alte Spa Generator Model Number S20FS 230 A Part Number 16428 002 Rotor Resistance 8 04 Ohms Stator Resistance 0 056 Ohms Excitation 0 41 Ohms Capacitors 31 5 µF qty 1 35 µF qty 2 Capacitor Part Number 300323 112 31 5 µF 300323 212 35 µF ENGINE Engine Manufacturer Honda Engine Model Number...

Page 5: ...te performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle assembly may cause excessive vibration and damage to the engine generator set DO NOT operate and or store the unit outside during inclement weather without adequate protection from the elements Failure t...

Page 6: ...ame amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an air compressor it will require more starting current If it is connected to a light load or no load such as a power saw it will require less starting current The exact requirement will also vary with the brand or design ...

Page 7: ...el surface before you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized Engine failures resulting from inadequate or improper lubricant are considered abuse and not covered by the generator or engine manufacturer s warranty OIL RECOMMENDATIONS Outdoor temperatures determine the proper oil viscosity for the engines Winco re...

Page 8: ...t engines are NEGATIVE GROUND Use extreme caution when connecting the battery Connect the NEGATIVE battery terminal to GROUND For your safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connections are clean an tight Reverse the sequence when disconnecting disconnect the negative cable first These eng...

Page 9: ...utes If the choke knob was pulled to the CLOSED position to start the engine gradually push it to the OPEN position as the engine warms up To stop the engine in an emergency simply turn the engine switch to the OFF position Under normal conditions use the following procedure Refer to the instructions provided by the equipment manufacturer Move the throttle lever to the MIN position Some engine app...

Page 10: ...s Sta Bil or equivalent will minimize the formation of gum deposits during storage The additive may be added to gasoline in the engines fuel tank or to gasoline in a storage container A Add the fuel stabilizer to the fuel in the tank and run for 2 minutes to circulate the stabilizer throughout the fuel system B If you choose to remove the remaining fuel from the fuel tank it must be drained into a...

Page 11: ...references STANDARD PORTABLE GENERATOR Your WINCO portable generator ships with a bonded neutral You can safely use this generator without external grounding as long as all loads are powered through the receptacle panel VEHICLE MOUNTED GENERATOR Your WINCO portable generator ships with a bonded neutral When mounted to a vehicle to safely distribute power it is necessary that the generator frame is...

Page 12: ...bution panel must be installed by a licensed electrician according to all applicable codes The electrician will move the critical circuits to be powered during the outage to the emergency panel Keep in mind only a limited amount of amperage is available from the generator set Some circuit breakers may still have to be turned off to prevent an overload on the generator during the initial start up S...

Page 13: ...UT Generator Load Speed RPM Frequency Hz Voltage 120V Recpt 240V Recpt None 3600 60 0 120V 240V Half 3600 60 0 120V 240V Full 3510 58 5 120V 240V The speed of the engine was carefully adjusted at the factory so that the generator produces the proper voltage and frequency For normal usage the speed setting should not be changed If the generator is being run continuously on a very light load it is o...

Page 14: ...r will light up the oil icon and the word change will flash Once the oil has been changed press and hold the cycle button for approximately 5 seconds until the warning has been removed from the display to reset the warning The meter will then remind you of oil changes on the appropriate schedule for your generator It is important to remember that the engine manufacturer recommends changing the oil...

Page 15: ...he gasket contacts the oil filter adapter then tighten the oil filter 1 2 to 3 4 turns F Replace oil drain bolt making sure the sealing washer is in place G Remove the oil filler cap and refill with new oil Make sure to use the proper grade oil based on your operating temperature NOTE This engine requires 57 6 ounces 1 8 quarts of oil if it is completely drained Use caution when refilling the engi...

Page 16: ... damage the engine Replace annually or every 300 hours of operation Always replace with the same spark plug that came in the engine and check gap before installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit ENGLISH Inspection Cleaning CKET AIR CLEANER COVER LATCH AIR CLEANER CASE PACKING FOAM FILTER ELEMENT PAPER FILTER ELEMENT AIR CLEANER COVER WING NUT AIR...

Page 17: ...B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the operator and destructive to the equipment CLEANING Remove dirt and debris with a cloth or brush CAUTION EQUIPMENT DAMAGE DO NOT use high pressure spray to clean either the engine or the generator The high pressu...

Page 18: ...efective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded Insufficient ventilation No output voltage Short in load disconnect Tripped or defective circuit breaker Broken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective rotor field Shorted capacitor Shorted diodes on rotor GFCI recepta...

Page 19: ...19 OPM 151 A WIRING DIAGRAM GND GND GND GND GND GND N N N N N N N G3 G3 G3 G3 G3 G3 G3 G3 G3 G3 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 ...

Page 20: ...and Purchaser s sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired or replaced For warranty service return the product within the warranty period to your nearest WINCO Authorized Service Center or to WINCO in Le Center Minnesota Duration...

Reviews: