23
General characteristics
Wilo-RAIN1
Admissible fluid
PH 5 to 8
Motor protection
Integrated thermal protection probe
Admissible fluid temperature
+ 5 °C up to + 30 °C
Noise level
up to 59 dB(A) (at 1 m from unit with wood plate wall in acoustic room)
Dimensions (LxWxH)
642 x 260 x 770
Break-tank volume
11 liters
Discharge connection
Rp 1″ threaded swivel-nut
Suction connection
Rp 1″ threaded swivel-nut
City main water connection
R 3/4″ (male)
Break-tank overflow
Install a drainage pipe Ø19-21 (to be provided by the customer). In case of a
very large leakage, an opening allows the water to flow freely according to EN
1717
Net weight (+/- 10 %)
26 kg
5.3
Dimensions
See Fig. 1
5.4
Scope of delivery
The Wilo-RAIN1 package includes:
See Fig. 2
ƒ
System,
ƒ
Float switch,
ƒ
Screw anchors,
ƒ
Installation and operating instructions,
ƒ
Stickers “No drinking water” and “Do not allow to freeze/do not expose to frost".
6
Description
6.1
Product description (see Fig. 3-4)
The system features a self-priming centrifugal pump that delivers rainwater sucked
from a storage tank (Fig. 4, rep. 17) to the points of consumption trough installation
pipes (Fig. 4, rep. 16).
The controller (Fig. 3, rep. 2) simultaneously ensures:
ƒ
The water continuity by switching the three-way valve (Fig. 3, item 6) to the mains
water network when the rainwater level in the rainwater storage tank is too low.
ƒ
The automatic start and stop of the pump.
ƒ
The pump’s dry-running protection in case of water shortage.
The 11-litre break tank (Fig. 3, rep. 3.) is designed according to the EN1717 standard
(AB type disconnection) and ensures a separation of the rainwater from the mains net-
work by means of an air gap.
The break tank is filled with city mains water through a float valve (Fig. 3-4, rep. 4). In
case of failure, the water overflow goes freely to the drain. The hose collecting the
overflow (Fig. 3-4, rep. 9) is not included.
Fig. 3 and 4 legends
Black arrow: suction
White arrow: discharge
1.
Pump set
2.
Control module
3.
Break tank
4.
Mains water network connection (G3/4″)
5.
Float switch to be installed inside the rainwater storage tank
6.
Three-way valve
7.
Discharge hose connection (G1″ swivel nut)
8.
Suction hose connection (G1″ swivel nut)
9.
Drainage connection towards wastewater (Ø19)
Summary of Contents for 2551468
Page 2: ...Fig 1 Fig 3 Fig 2 122 75 Rp 3 4 Rp 1 Rp 1 a b...
Page 3: ...Fig 4 Fig 5 Fig 6...
Page 4: ...Fig 11 Fig 7 Fig 9 Fig 10 Fig 8 Max 5 N m Max 5 N m...
Page 5: ...5 Deutsch 6 English 19 Fran ais 31 Nederlands 44 57 esky 72...
Page 58: ...el 58 WILO SE 2020 02 1 1 1 2 2 1 2 2...
Page 59: ...el Wilo RAIN1 59 2 3 2 4 IEC VDE 2 5 IEC VDE 2 6 2 7 2 8 4...
Page 65: ...el Wilo RAIN1 65 7 1 7 2 1 7 3 Fig 3 4 Fig 5 Fig 3 12 Fig 6 Fig 7 Fig 8 11 Fig 9 3 8 mm 16 mm...
Page 67: ...el Wilo RAIN1 67 4 G3 4 7 G1 8 G1 7 5 RCD 30 mA RAIN1 0 3 ohm 4...
Page 69: ...el Wilo RAIN1 69 2 7 3 10 9...
Page 71: ...el Wilo RAIN1 71 www wilo recycling com...
Page 88: ......
Page 89: ......
Page 90: ......