Operating Manual
2.
Cut the cable strap which holds the battery.
Exchange battery and use a new maximum
2,5 mm wide cable strap.
Use only batteries of type Alkaline AAA.
Illustration of circuit board with battery in the wiring diagram
on page 33.
Fault
An overview of possible faults which make a normal operation impossible.
informations
Illustration
Fault information
Cause
Remedy
Yellow light on middle
The water tank is full
see instructions for
LED with emptying
or malfunction at the
emptying below resp.
symbol and
water pump (accessory)
check pump drainage
FULL
on display
Red light on
Pressure or temperature in the
Check filter and
right warning-LED
high-pressure element
dehumidifier for dirt in
HIGH Temp
on display
too high
the airstream
Red light on
Room temperature
Place dehumidifier in
right warning-LED
above normal operating
specified temperature
AMBIENT TEMP
sector
sector of 3°-35°C
on display
Red light on
right warning-LED
1.
EVAP FAIL
Call for authorized
SENSOR FAIL
on display Thermo sensor of
service technician
One of the internal
evaporator defective
sensors is defective
2. COND FAIL
Call for authorized
Use +/- buttons in order to Thermo sensor of
service technician
change between
the condensor defective
3 possible faults
3. ROOM FAIL
Call for authorized
Built-in roomtemperature
service technician
sensor defective
Red light on
Leak in the cooling
Call for authorized
right warning-LED
circuit
service technician
LP STOP
on display
12 of 33
Sensor Fail
Summary of Contents for 3100430
Page 1: ...Perfection is our aim Manual Dehumidifiers KT 330 KT 430 KT 830...
Page 17: ...16 of 33 Checklist User...
Page 18: ...17 of 33 Checklist User...
Page 19: ...18 of 33 Checklist User...
Page 20: ...19 of 33 Checklist User...
Page 29: ...28 of 33 Exploded View KT 330...
Page 31: ...30 of 33 Exploded View KT 430...
Page 33: ...32 of 33 Exploded View KT 830...