Operating Manual
Text displays
The dehumidifier has a built-in battery which makes it possible to read the display also
without
if not connected to a power supply. Without main power the following can be read:
main power
Button
keep pressed
and
shows the total energy consumption in kWh
press once
keep pressed
and
shows the total operating hours
press once
of the dehumidifier
Exchange of
If the hour meter is separated from the power supply and can no longer be read then
the Data
the cause is most probably an empty data store-battery.
store-battery
Procedure how to exchange the battery:
Warning:
Before exchanging the battery make sure that the dehumidifier is disconnected from the
power supply.
1.
11 of 33
Measure
Loosen screws on both sides
of the touchscreen and lift
the touchscreen carefully.
Explanation