WILMS 3100430 Manual Download Page 1

Perfection is our aim

Manual

Dehumidifiers

    KT 330 / KT 430 / KT 830

  

Summary of Contents for 3100430

Page 1: ...Perfection is our aim Manual Dehumidifiers KT 330 KT 430 KT 830...

Page 2: ...recautions to prevent the possibility of property damage and or personal injury Contents This service manual covers the following main topics Page Introduction Overview 1 General information EU Confor...

Page 3: ...ut prior notice or obligation EU Conformity Declaration Dehumidifier Type KT 330 KT 430 KT 830 covered by this declaration is in conformity with the following directives 2006 42 EG Directive on the Sa...

Page 4: ...ust be installed in a room without a permanently active ignition source for example open fire a gas device or electric air heater in operation Keep the ventilation openings free of foreign objects dur...

Page 5: ...ed air circulation through the dehumidifiers the air humidity is continuously reduced whereby achieving rapid but gentle drying Illustration This illustration gives an overview of the dehumidifier Han...

Page 6: ...ocket for external hygrostat Display for temperature relative humidity hour meter and kW h consumption Hour meter and display for consumed kW h without 230V connection Adjustable service interval coun...

Page 7: ...Open the cardboard box on the top 2 Place the cardboard box so that the handle and wheels are on the floor 3 Pull the handle and wheel of the dehumidifier out while lying down 4 Loosen the finger scre...

Page 8: ...om areas of 4 m The device must be installed in a room without permanently active ignition sources e g open fire a gas appliance in operation or an electric air heater in operation Optimal Make sure t...

Page 9: ...e see instructions below Replacing Note Observe local working environment rules regarding heavy lifting of the dehumidifier Hoist Crane Lift by lifting strap Stacking Max 2 dehumidifiers should be sta...

Page 10: ...the operation of the hygrostat function and the display texts the built in hygrostat Step Button keep HYG SET RHXX flashes for 5 seconds pressed The dehumidifier then switches to the controlled opera...

Page 11: ...er 5 seconds of flashing and the function is activated if not already done When the time for the service intervall has been reached the display shows SERVICE Shortly press in order to preset a new ser...

Page 12: ...ssed and shows the total operating hours press once of the dehumidifier Exchange of If the hour meter is separated from the power supply and can no longer be read then the Data the cause is most proba...

Page 13: ...ight warning LED high pressure element dehumidifier for dirt in HIGH Temp on display too high the airstream Red light on Room temperature Place dehumidifier in right warning LED above normal operating...

Page 14: ...empty the water tank Step Illustration 1 Pull the handle in front of the water tank to remove the tank halfway out of the dehumidifier 2 Grab the side handles of the tank and lift clear off the dehumi...

Page 15: ...n KT Type Part No Hygrostat When a hygrostat is connected the dehumidifier can operate continuously depending on the relative humidity in the room Hygrostat with 1 5 m cable and all 3102004 jack plug...

Page 16: ...on the refrigerant equipment or other related parts you have to have suitable fire extinguishing equipment at hand Powder extinguisher A B C CO2 extinguisher Inspection The inspection checklist has be...

Page 17: ...16 of 33 Checklist User...

Page 18: ...17 of 33 Checklist User...

Page 19: ...18 of 33 Checklist User...

Page 20: ...19 of 33 Checklist User...

Page 21: ...by tilting it outwards 2 Remove the filter either rinse it with lukewarm soapy water or vacuum clean it if the filter is only a little dirty Change the filter if it is very dirty see chapter Spare pa...

Page 22: ...ance do NOT reset the service interval counter Annual Return the dehumidifier to an authorised service centre at the end of the service interval or maintenance or at least once a year or maintenance T...

Page 23: ...t in hygrostat on page 9 Yellow control lamp The water tank is full or pump Empty the water tank or illuminates accessory blocks eleminate pump Display shows FULL blockade Red control lamp Fault which...

Page 24: ...30 KT 430 KT 830 Operating range himidity RH RH hysteresis RH Operating range Temperat C Power suply V Hz Max amperage A 3 6 4 1 5 6 Max input kW 0 8 0 9 1 3 Air output m h 300 400 800 Refrigerant R45...

Page 25: ...Measurements Illustration KT 330 KT 430 KT 830 L 412 mm 530 mm 535 mm W 510 mm 540 mm 560 mm H 650 mm 743 mm 820 mm TH 740 mm 820 mm 900 mm 24 of 33...

Page 26: ...y takes place Do not mix refrigerants in recovery units and specially not in the cylinders 4 Start the recovery machine and operate it according to the instructions of the manufacturer Do not overfill...

Page 27: ...ries are also with the chemical signs Hg mercury Cd cadmium or Pb lead These are particularly harmful substances Therefore it is very important that such batteries are collected on an approved collect...

Page 28: ...n 3102016 1 not shown 3103167 3 not shown 3103885 1 not shown 3103877 1 not shown 3102039 1 27 of 33 Lock washer Thermostatic valve Schrader valve Wheel cover Foot Bushing Water stop sensor Float Hygr...

Page 29: ...28 of 33 Exploded View KT 330...

Page 30: ...6 1 not shown 3103167 3 not shown 3103885 1 not shown 3103886 1 not shown 3102039 1 29 of 33 Spare Part List KT 430 Description Guard including filter Filter Water tank complete Front cover complete H...

Page 31: ...30 of 33 Exploded View KT 430...

Page 32: ...03167 3 not shown 3103885 1 not shown 3108216 1 not shown 3102039 1 31 of 33 Fan motor Exhaust grid Screw M 6 x 35 Control panel Cable 3 5 m Solenoid valve Coil for solenoid valve Fan blade 300 mm Exp...

Page 33: ...32 of 33 Exploded View KT 830...

Page 34: ...it B5 External hygrostat optional M1 Compressor B6 Thermostat only KT580 M2 Fan motor B7 Overtemp only KT 580 R1 Heating element only KT 580 B8 External pump alarm optional S1 Heating element on off D...

Reviews: