25
9.2 Model FLM-CM
Magnetostrictive level transmitter, model FLM-CM
Guide tube
Ø 6 mm (max. 1,000 mm)
Process connection
Mounting thread downwards
■
G 1/2 ... G 2
■
1/2 NPT ... 2 NPT
Other process connections on request
Materials
Wetted parts
Stainless steel 1.4571 (316Ti)
Connection head
Stainless steel 1.4305 (303)
Insertion length
100 ... 1,000 mm
Measurement accuracy
±2.5 mm
Resolution
0.1 mm
Electrical connection
Circular connector M12
Supply voltage
DC 8 ... 30 V
Output signal
4 ... 20 mA (NAMUR NE43)
Operating pressure
Depending on the float, max. 40 bar
Operating temperature
-40 ... +125 °C
Ambient temperature
-40 ... +85 °C
Ingress protection per EN 60529
IP68
Configuration
Via USB adapter with corresponding software and a
standard computer
Order number: 14361280
For further specifications see data sheet LM 20.05 and the order documentation.